Key result
Increased LA diameter and atrial ectopic burden predict ~131% greater AF risk in ESUS patients.
Why the study?
ICMs are useful for detecting subclinical AF in ESUS, but clinical predictors of AF in this population needed to be identified.
Do left atrial diameter and atrial ectopic burden predict the detection of atrial fibrillation in patients with embolic stroke of undetermined source?
Cohort (n=136)
No
Do left atrial diameter and atrial ectopic burden predict the detection of atrial fibrillation in patients with embolic stroke of undetermined source?
The combination of left atrial diameter ≥38.5 mm and atrial ectopic burden ≥0.050% strongly predicts the detection of subclinical atrial fibrillation in patients with embolic stroke of undetermined source.
BACKGROUND AND PURPOSE: An insertable cardiac monitor (ICM) has been demonstrated to be a useful tool for detecting subclinical atrial fibrillation (AF) in patients with embolic stroke of undetermined source (ESUS). This study aimed to identify the clinical predictors of AF in ESUS patients with ICMs. METHODS: We retrospectively selected consecutive patients with an ICM implanted for AF detection following ESUS. The primary endpoint was defined as any AF episode lasting for longer than 5 min. The atrial ectopic burden (AEB) was calculated as the percentage of the number of conducted QRS from atrial ectopy on Holter monitoring. RESULTS: <0.001) than those without AF. The areas under the receiver operating characteristic curves were 0.795 and 0.816 for the LAD and log-transformed AEB, respectively, for the best cutoff values of 38.5 mm for LAD and 0.050% for AEB. AF lasting ≥5 min was detected in 34.6% (9/26) of patients with LAD ≥38.5 mm and AEB ≥0.050%, and in 0% (0/65) of those with LAD <38.5 mm and AEB <0.050%. CONCLUSIONS: AF was detected in a significant proportion of ESUS patients during a 6.6-month follow-up. The LAD and AEB are good predictors of AF and might be useful for AF risk stratification in ESUS patients.
No takes yet. Share an insight, caveat, or question.
Lee et al. (2021) conducted a cohort in Embolic stroke of undetermined source (ESUS) (n=136). Insertable cardiac monitor (ICM) was evaluated on Detection of any atrial fibrillation episode lasting ≥5 minutes (HR 2.311, 95% CI 1.463-3.649, p=<0.001). Left atrial diameter ≥38.5 mm and atrial ectopic burden ≥0.050% strongly predicted atrial fibrillation ≥5 minutes in ESUS patients, with a 34.6% incidence versus 0% in those below both thresholds.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: