Key result
An equivalent electronic circuit model successfully simulated the hemodynamics of left ventricular aneurysms, demonstrating that dyskinetic aneurysms have a considerably greater impact on ventricular function than akinetic aneurysms.
Answers are grounded in this paper and cite their sources.
An equivalent electronic circuit model can realistically simulate the hemodynamic effects of akinetic and dyskinetic left ventricular aneurysms.
The purpose of our study was to simulate the hemodynamics of left ventricular function after left ventricular aneurysm (LVA) of various sizes and to validate the results of this computer based simulation with patient data. We developed an equivalent electronic circuit (EEC) that reflects the hemodynamic conditions of LVA (after acute myocardial infraction) while taking into consideration the resetting of the sympathetic nervous tone in the heart and systemic circuit, the fluctuating intrathoracic pressure during respiration and passive relaxation of the ventricle during diastole. The key feature of the EEC was a subcircuit representing the LVA, with a subcircuit to measure ventricular blood volume (i.e. intraventricular "shunting" of blood flow during systole and diastole) between the unaffected section of the left ventricle and its aneurysm. This EEC model can simulate akinetic or dyskinetic LVAs of different sizes and provides realistic beat-to-beat ventricular blood flow and pressure tracings that were validated by pressure-volume loop diagrams and by published patient data. In agreement with published data, simulated dyskinetic LVAs have a considerably greater impact on ventricular function than akinetic LVAs. The hemodynamic effects of ventricular systolic dysfunction following LVA were also evaluated. We conclude that the EEC model qualitatively and to a significant degree quantitatively represents conditions in patients with a dyskinetic or an akinetic LVA and provides realistic beat-to-beat ventricular blood flow and pressure tracings.
No takes yet. Share an insight, caveat, or question.
Sever et al. (2012) studied Left ventricular aneurysm. Equivalent electronic circuit (EEC) simulation was evaluated on Hemodynamic variables (ejection fraction, end-diastolic volume, end-diastolic pressure). An equivalent electronic circuit model successfully simulated the hemodynamics of left ventricular aneurysms, demonstrating that dyskinetic aneurysms have a considerably greater impact on ventricular function than akinetic aneurysms.
Synapse has enriched 10 related papers. Consider them for comparative context: