Key result
Pre-TAVR assessment using a PET/CT scanner was safely performed in a 79-year-old man, leading to successful TAVR implantation with no evidence of leak at 30 days.
Why the study?
Exponential growth in TAVR cases may lead to CT scanner resource saturation, prompting evaluation of alternative resources such as PET/CT scanners for pre-procedural planning.
Can pre-TAVR assessment be safely and effectively performed on a PET/CT machine in patients with severe aortic stenosis?
Case Report (n=1)
No
Can pre-TAVR assessment be safely and effectively performed on a PET/CT machine in patients with severe aortic stenosis?
Pre-TAVR assessment can be successfully performed using a PET/CT scanner, offering a potential solution to standard CT scanner resource saturation.
BACKGROUND: Since the first transcatheter aortic valve replacement (TAVR), there has been an exponential increase in the number of patients diagnosed and treated for aortic stenosis. CASE SUMMARY: A 79-year-old man, with severe symptomatic aortic stenosis and a past medical history of coronary artery bypass in 2006 and percutaneous coronary stent implantation in 2016, presented to our Heart Valve Center for pre-TAVR assessment. Preprocedural computed tomography angiography was completed on a positron emission tomography (PET)/computed tomography (CT) machine. The patient underwent successful implantation of TAVR, with no evidence of leak on postoperative echocardiographic assessment on days 1 and 30. DISCUSSION: Cardiac computed tomography angiography is the established gold standard for pre-TAVR evaluation in patients with no absolute contraindications; we may soon face a resource saturation problem. Therefore, we should aim to use our resources wisely. NOVELTY: A possible solution to the issue of CT scanner saturation lies in using our resources more efficiently: for example, pre-TAVR planning could be performed on PET/CT scanners, providing comparable results. TAKE-HOME MESSAGE: Pre-TAVR assessment can be safely performed on a PET/CT machine.
No takes yet. Share an insight, caveat, or question.
Passaniti et al. (2026) conducted a case report in Severe symptomatic aortic stenosis (n=1). Preprocedural computed tomography angiography on a positron emission tomography (PET)/computed tomography (CT) machine was evaluated on Successful implantation of TAVR and postoperative leak. Pre-TAVR assessment using a PET/CT scanner was safely performed in a 79-year-old man, leading to successful TAVR implantation with no evidence of leak at 30 days.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: