Key result
Cardiac MRI at 1.5-T was performed safely without adverse effects or alteration of pacemaker function in 9 CHD patients with MRI-conditional pacemaker systems.
Why the study?
Does 1.5-T cardiac MRI safely provide diagnostic images in CHD patients with MRI-conditional pacemaker systems?
Observational (n=9)
Does 1.5-T cardiac MRI safely provide diagnostic images in CHD patients with MRI-conditional pacemaker systems?
Cardiac MRI at 1.5-T can be safely performed and yields diagnostic images in patients with congenital heart disease and MRI-conditional pacemakers.
OBJECTIVES: In patients with CHD, cardiac MRI is often indicated for functional and anatomical assessment. With the recent introduction of MRI-conditional pacemaker systems, cardiac MRI has become accessible for patients with pacemakers. The present clinical study aims to evaluate safety, susceptibility artefacts, and image reading of cardiac MRI in patients with CHD and MRI-conditional pacemaker systems. Material and methods CHD patients with MRI-conditional pacemaker systems and a clinical need for cardiac MRI were examined with a 1.5-T MRI system. Lead function was tested before and after MRI. Artefacts and image readings were evaluated using a four-point grading scale. RESULTS: A total of nine patients with CHD (mean age 34.0 years, range 19.5-53.6 years) received a total of 11 cardiac MRI examinations. Owing to clinical indications, seven patients had previously been converted from conventional to MRI-conditional pacemaker systems. All MRI examinations were completed without adverse effects. Device testing immediately after MRI and at follow-up showed no alteration of pacemaker device and lead function. Clinical questions could be addressed and answered in all patients. CONCLUSION: Cardiac MRI can be performed safely with high certainty of diagnosis in CHD patients with MRI-conditional pacemaker systems. In case of clinically indicated lead and box changing, CHD patients with non-MRI-conditional pacemaker systems should be considered for complete conversion to MRI-conditional systems.
No takes yet. Share an insight, caveat, or question.
Al‐Wakeel et al. (2015) conducted an observational in Congenital Heart Disease (CHD) (n=9). Cardiac MRI (1.5-T) was evaluated on Safety, susceptibility artefacts, and image reading. Cardiac MRI at 1.5-T was performed safely without adverse effects or alteration of pacemaker function in 9 CHD patients with MRI-conditional pacemaker systems.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: