Retrospective review demonstrates high diagnostic accuracy for coaxial cutting needle biopsy in thoracic lesions, highlighting exceptional yield for benign conditions.
PURPOSE: To determine the utility of coaxial transthoracic needle biopsy (TNB) with use of a 20-gauge automated cutting biopsy needle in the diagnosis of thoracic lesions. MATERIALS AND METHODS: A retrospective review was performed in 122 patients. Computed tomography was used to guide coaxial TNB, which was performed with aspirating (n = 87) and automated cutting (n = 99) needles. The sensitivities for malignant and benign lesions were determined, with a comparison of the relative yields from the two techniques. RESULTS: The overall diagnostic yield for coaxial TNB was 88%. For malignancy the sensitivity was 95%, whereas a specific benign diagnosis was obtained in 91%. Although no difference was found for fine-needle aspiration versus core biopsy of malignant lesions (92% vs 86%), a statistically significant difference was found for benign lesions (44% vs 100%, P<.05). Pneumothorax occurred in 54%. CONCLUSION: Coaxial TNB performed with an automated cutting needle helps provide a diagnosis in the majority of patients with focal chest disease and is particularly useful in the diagnosis of benign lesions.
No takes yet. Share an insight, caveat, or question.
Klein et al. (1996) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: