Key result
Computational fluid dynamics modeling of 5 cases showed that serial stenoses with spacing ratios <7 caused larger errors in FFR measurements, whereas iFR measurements had negligible interference.
Why the study?
The hemodynamic interference of serial stenoses challenges functional severity assessment via FFR, and the mechanism underlying iFR in this setting remained ambiguous due to the lack of quantitative definition of hemodynamic interference.
Does the hemodynamic interference of serial stenoses impact iFR measurements differently than FFR measurements?
Does the hemodynamic interference of serial stenoses impact iFR measurements differently than FFR measurements?
Computational modeling demonstrates that iFR is less affected by hemodynamic interference from serial stenoses compared to FFR.
Answers are grounded in this paper and cite their sources.
May favor iFR in serial stenoses; leaves open need for clinical validation.
The hemodynamic interference of serial stenoses poses challenges for identifying the functional severity using the fractional flow reserve (FFR) method. The instantaneous wave-free ratio (iFR), i.e., the distal-to-proximal pressure ratio at 75% of diastole, was recently proposed to overcome the disadvantages of the FFR. However, the underlying mechanism remained ambiguous due to the lack of quantitative definition of hemodynamic interference. The objective of this study is to quantitatively define the hemodynamic interference and then examine its role on the FFR and iFR measurements. Pressure distributions, velocity fields, and Q-criterion which identifies vortices, were obtained through the computational fluid dynamics (CFD) for five cases with spacing ratios at 1, 3, 5, 7, and 10. The hemodynamic interference was identified using vortex structures which were quantified by Q-criterion. Results have shown that a spacing ratio of 7 or larger was interference-free. Serial stenoses with a smaller spacing ratio led to a larger hemodynamic interference, and thus, larger errors in the FFR measurements compared to the spacing ratio of 7. Moreover, the underestimation of the first stenosis lesion has been observed, even in interference-free cases due to the nature of hyperemia. However, the hemodynamic interference of the serial stenoses has a negligible impact on the iFR measurement, regardless of the spacing ratio. Our results demonstrated that the quantification of the hemodynamic interference in serial stenoses provided a better understanding of its role on the pressure measurements, which could be further exploited for the optimal treatment of serial stenoses.
No takes yet. Share an insight, caveat, or question.
Ju et al. (2019) studied Serial stenoses (n=5). Instantaneous wave-free ratio (iFR) vs. Fractional flow reserve (FFR) was evaluated on Hemodynamic interference and measurement errors. Computational fluid dynamics modeling of 5 cases showed that serial stenoses with spacing ratios <7 caused larger errors in FFR measurements, whereas iFR measurements had negligible interference.