Key result
Navigated free-breathing 3D LGE-CMR yielded similar scar mass compared to breath-hold imaging, while high-resolution free-breathing increased scar edge sharpness.
Why the study?
Does navigated free-breathing 3D LGE-CMR provide comparable scar mass quantification and image quality to breath-hold 3D LGE-CMR in patients with cardiomyopathy?
Observational (n=48)
No
Does navigated free-breathing 3D LGE-CMR provide comparable scar mass quantification and image quality to breath-hold 3D LGE-CMR in patients with cardiomyopathy?
Navigated free-breathing 3D LGE-CMR is a reliable alternative to breath-hold imaging for myocardial scar quantification, enabling higher spatial resolution that improves scar sharpness and reduces partial volume overestimation.
Answers are grounded in this paper and cite their sources.
Navigated free-breathing 3D LGE-CMR may enable comparable scar quantification with sharper edges in cardiomyopathy; leaves open prospective validation before routine adoption.
PURPOSE: To compare breath-hold (BH) with navigated free-breathing (FB) 3D late gadolinium enhancement cardiac MRI (LGE-CMR) MATERIALS AND METHODS: Fifty-one patients were retrospectively included (34 ischaemic cardiomyopathy, 14 non-ischaemic cardiomyopathy, three discarded). BH and FB 3D phase sensitive inversion recovery sequences were performed at 3T. FB datasets were reformatted into normal resolution (FB-NR, 1.46x1.46x10mm) and high resolution (FB-HR, isotropic 0.91-mm voxels). Scar mass, scar edge sharpness (SES), SNR and CNR were compared using paired-samples t-test, Pearson correlation and Bland-Altman analysis. RESULTS: Scar mass was similar in BH and FB-NR (mean ± SD: 15.5±18.0 g vs. 15.5±16.9 g, p=0.997), with good correlation (r=0.953), and no bias (mean difference ± SD: 0.00±5.47 g). FB-NR significantly overestimated scar mass compared with FB-HR (15.5±16.9 g vs 14.4±15.6 g; p=0.007). FB-NR and FB-HR correlated well (r=0.988), but Bland-Altman demonstrated systematic bias (1.15±2.84 g). SES was similar in BH and FB-NR (p=0.947), but significantly higher in FB-HR than FB-NR (p<0.01). SNR and CNR were lower in BH than FB-NR (p<0.01), and lower in FB-HR than FB-NR (p<0.01). CONCLUSION: Navigated free-breathing 3D LGE-CMR allows reliable scar mass quantification comparable to breath-hold. During free-breathing, spatial resolution can be increased resulting in improved sharpness and reduced scar mass. KEY POINTS: • Navigated free-breathing 3D late gadolinium enhancement is reliable for myocardial scar quantification. • High-resolution 3D late gadolinium enhancement increases scar sharpness • Ischaemic and non-ischaemic cardiomyopathy patients can be imaged using free-breathing LGE CMR.
No takes yet. Share an insight, caveat, or question.
Bizino et al. (2018) conducted an observational in Ischaemic and non-ischaemic cardiomyopathy (n=48). Navigated free-breathing 3D LGE-CMR vs. Breath-hold 3D LGE-CMR was evaluated on Scar mass (mean difference 0.00 g, p=0.997). Navigated free-breathing 3D LGE-CMR yielded similar scar mass compared to breath-hold imaging, while high-resolution free-breathing increased scar edge sharpness.