Authors
335 ears from 210 childred in which tympanometry initially indicated middle ear pressure less than or equal to -100 mm H2O or a flat tympanogram have been reinvestigated 3 years later. When the inital investigation was performed all children were 7 years old. The present study reveals that 25% of these ears still have middle ear pressure less than or equal to -100 mm H2O and 16% middle ear pressure less than or equal to -150 mm H2O. In normal material of the same age group 9% have middle ear pressure less than or equal to -100 mm H2O and 4% middle ear pressure less than or equal to -150 mm H2O. The study also reveals effusion in 10% of ears with normal screening audiograms. In ears with normal screening audiograms and middle ear pressure greater than or equal to -145 mm H2O effusion was found in 5% and in ears with abnormal screening audiograms and middle ear pressure less than or equal to -150 mm H2O effusion was found in 81%. As tympanometric criterion for otologist referral, middle ear pressure less than or equal to -150 mm H2O or a flat tympanogram is suggested. The inclusion of tympanometry in routine screening for middle ear pathology in children is recommended.
No takes yet. Share an insight, caveat, or question.
Renvall et al. (1978) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: