Key result
Circumferentially uniform carotid plaque microstructures fail at higher stress and strain than mixed microstructures.
Why the study?
Linking clinically relevant non-invasive microstructural imaging to mechanical plaque characterisation could enable mechanically sensitive rupture risk indicators for atherosclerotic plaques.
Does ex vivo diffusion tensor imaging (DTI) provide insight into the mechanical properties and vulnerability of human carotid atherosclerotic plaques?
Does ex vivo diffusion tensor imaging (DTI) provide insight into the mechanical properties and vulnerability of human carotid atherosclerotic plaques?
Answers are grounded in this paper and cite their sources.
DTI links carotid plaque microstructure to mechanical stability; hypothesis-generating for in vivo vulnerability assessment.
Non-invasive microstructural characterisation has the potential to determine the stability, or lack thereof, of atherosclerotic plaques and ultimately aid in better assessing plaques’ risk to rupture. If linked with mechanical characterisation using a clinically relevant imaging technique, mechanically sensitive rupture risk indicators could be possible. This study aims to provide this link – between a clinically relevant imaging technique and mechanical characterisation within human atherosclerotic plaques. Ex vivo diffusion tensor imaging, mechanical testing, and histological analysis were carried out on human carotid atherosclerotic plaques. DTI-derived tractography was found to yield significant mechanical insight into the mechanical properties of more stable and more vulnerable microstructures. Coupled with insights from digital image correlation and histology, specific failure characteristics of different microstructural arrangements furthered this finding. More circumferentially uniform microstructures failed at higher stresses and strains when compared to samples which had multiple microstructures, like those seen in a plaque cap. The novel findings in this study motivate diagnostic measures which use non-invasive characterisation of the underlying microstructure of plaques to determine their vulnerability to rupture. Statements and Declarations The authors have no competing interests or declarations to declare.
No takes yet. Share an insight, caveat, or question.
Tornifoglio et al. (2022) studied Atherosclerotic plaques. Ex vivo diffusion tensor imaging (DTI) was evaluated on Mechanical properties and failure characteristics. Ex vivo diffusion tensor imaging of human carotid plaques revealed that circumferentially uniform microstructures failed at higher stresses and strains compared to those with multiple microstructures.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: