Localized corrosion, which usually appears as pitting, crevice corrosion (CC), or certain aspects of stress corrosion cracking (SCC), is a multi-step process. This review is organized by a consideration of the four steps involved in localized corrosion: (1) adsorption of the reactive anion on the oxide covered aluminum; (2) chemical reaction of the adsorbed anion with the aluminum ion in the aluminum oxide lattice or the precipitated aluminum hydroxide; (3) thinning of the oxide by dissolution; and (4) direct attack of the exposed metal by the anion, perhaps assisted by an anodic potential. The experimental work reported in the literature is evaluated within this framework.
No takes yet. Share an insight, caveat, or question.
R. T. Foley (1986) studied this question.