Key result
DGMS descriptor with KNN classifier achieves 98% accuracy in detecting hypertension from ultrasound images.
Why the study?
The study was designed to automate the detection of hypertension using ultrasound images and machine learning.
Does a Directional-Guided Motion Sensitive (DGMS) descriptor and Machine Learning algorithm accurately detect hypertension using four-chamber ultrasound images?
Observational (n=140)
No
Does a Directional-Guided Motion Sensitive (DGMS) descriptor and Machine Learning algorithm accurately detect hypertension using four-chamber ultrasound images?
A novel machine learning approach using a Directional-Guided Motion Sensitive descriptor on four-chamber ultrasound images can accurately distinguish between hypertensive patients and healthy controls.
Supports ML feasibility for hypertension detection on cardiac ultrasound; hypothesis-generating and should not yet change practice.
The current work proposes an efficient assessment of hypertension (HTN) using a Directional-Guided Motion Sensitive (DGMS) descriptor and Machine Learning (ML) algorithm. The main objective of the proposed work is to automate the detection of HTN using ultrasound (US) images. The four-chamber US images from 70 healthy subjects and 70 HTN patients are collected. A novel pipelined architecture has been developed in two stages with four phases: preprocessing, feature extraction using DGMS descriptor, feature ranking and selection, and classification using shallow K-Nearest Neighbor classifier. The proposed model has achieved a classification accuracy of 98% using a set of prominent features, predominating the performance attained by other approaches. This study suggests US contains predictive signals even when standard measures are normal and lays the groundwork for artificial intelligence-assisted cardiac assessment to aid quicker, more objective diagnosis and earlier treatment. If further validated on additional diverse patient data, the technology could be integrated into clinics to enhance HTN detection through automated, early discernment of subtle manifestations missed by human eyes and traditional metrics.
No takes yet. Share an insight, caveat, or question.
Gudigar et al. (2024) conducted an observational in Hypertension (n=140). Directional-Guided Motion Sensitive (DGMS) descriptor with Machine Learning vs. Other machine learning models was evaluated on Classification accuracy for hypertension detection. The proposed Directional-Guided Motion Sensitive (DGMS) descriptor with a weighted K-Nearest Neighbor classifier achieved 98% accuracy, 98.4% specificity, and 97.5% sensitivity in detecting hypertension from ultrasound images.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: