Key result
Biological aortic valve replacement shows no long-term mortality benefit over mechanical valves in dialysis patients.
Why the study?
There is no consensus on the choice of aortic valve prosthesis for patients with end-stage renal failure undergoing aortic valve replacement.
Does biological aortic valve replacement reduce mortality or complications compared to mechanical aortic valve replacement in patients on dialysis?
Cohort (n=335)
Yes
Does biological aortic valve replacement reduce mortality or complications compared to mechanical aortic valve replacement in patients on dialysis?
Effect estimate: aHR 1.33 (95% CI 0.84-2.13)
p-value: p=0.22
Biological and mechanical aortic valve prostheses yield similar mortality and complication rates in dialysis patients, supporting the use of biological valves to avoid systemic anticoagulation.
Mortality equivalence in dialysis may favor biological valves to avoid anticoagulation; leaves open optimal choice pending randomized trials.
Background: There is no consensus on the choice of aortic valve prosthesis for patients with end-stage renal failure. We analyzed short- and long-term complications in dialysis patients who underwent aortic valve replacement (AVR) with either a biological (bAVR) or a mechanical (mAVR) prosthesis. Methods: All patients on dialysis who underwent bAVR or mAVR in Sweden from 1995 to 2017 (n=335) were included in a nationwide, population-based, observational, cohort study. Short and long-term complications were compared. Long-term mortality was compared with multivariable Cox regression analysis adjusted for age, sex, comorbidities, and a propensity score-matched model. Median follow-up was 2.8 (range, 0-16) years. Results: Biological and mechanical valves were implanted in 253 (75.5%) and 82 (24.5%) patients, respectively. The bAVR patients were older and had more comorbidities. There was no significant difference in early complication rate. Thirty-day mortality was 9.1% in bAVR and 7.3% in mAVR patients (P=0.62). The multivariable Cox regression model did not show significant difference in mortality risk between bAVR and mAVR patients [adjusted hazard ratio (aHR) 1.33; 95% CI: 0.84-2.13; P=0.22]. The results were confirmed in the propensity-score matched model. The rate of aortic valve reoperations did not differ significantly between the bAVR and mAVR group. Conclusions: The short- and long-term complication rate is high, and the expected life expectancy limited, in dialysis patients undergoing AVR, without significant difference between biological and mechanical prostheses. The results suggest that biological valve prosthesis, avoiding systemic anticoagulation, is appropriate in most dialysis patients.
No takes yet. Share an insight, caveat, or question.
Perrotta et al. (2022) conducted a cohort in End-stage renal failure on dialysis requiring aortic valve replacement (n=335). Biological aortic valve replacement (bAVR) vs. Mechanical aortic valve replacement (mAVR) was evaluated on Long-term mortality (aHR 1.33, 95% CI 0.84-2.13, p=0.22). Biological aortic valve replacement showed no significant difference in long-term mortality compared to mechanical valves in dialysis patients (aHR 1.33; 95% CI 0.84-2.13; P=0.22).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: