Key result
The HEART system, utilizing fog computing for wearable ECGs, achieved a very high success rate in event detection and sustained battery operation for up to a full week without recharging.
Why the study?
Existing wearable ECGs have limited accuracy and rely on external resources to analyze signals and evaluate heart activity.
A novel fog computing-based wearable ECG system demonstrates high accuracy for local event detection and low power consumption, enabling up to a week of continuous monitoring.
Answers are grounded in this paper and cite their sources.
May enable week-long wearable ECG monitoring in select settings; leaves open need for clinical validation trials.
Heart disease and stroke are becoming the leading causes of death worldwide. Electrocardiography monitoring devices (ECG) are the only tool that helps physicians diagnose cardiac abnormalities. Although the design of ECGs has followed closely the electronics miniaturization evolution over the years , existing wearable ECGs have limited accuracy and rely on external resources to analyze the signals and evaluate heart activity. In this paper, we work towards empowering the wearable device with processing capabilities to locally analyze the signal and identify abnormal behaviour. The ability to differentiate between normal and abnormal heart activity significantly reduces (a) the need to store the signals, (b) the data transmitted to the cloud, (c) the overall power consumption and (d) the confidentiality of private data. Based on this concept, the HEART system presented in this work combines wearable embedded devices, mobile edge devices, and cloud services to provide on-the-spot, reliable, accurate, and instant heart monitoring. The wearable device is remotely trained by a physician to learn to accurately identify critical events related to each particular patient. Following this training session, the wearable device becomes capable of interpreting a large number of heart abnormalities without relying on cloud services and edge resources, when the medical doctor is not present. The Fog computing approach extends the cloud computing paradigm by migrating data-processing closer to the production site, thus accelerating the system’s responsiveness to events. The HEART system’s performance concerning the accuracy of detecting abnormal events and the power consumption of the wearable device is evaluated. Results indicate that a very high success rate can be achieved in terms of event detection ratio and the battery is able to sustain operation up to a full week without the need for a recharge.
No takes yet. Share an insight, caveat, or question.
Akrivopoulos et al. (2019) studied Cardiac abnormalities. HEART system (fog computing-based wearable ECG) was evaluated on Accuracy of detecting abnormal events and power consumption. The HEART system, utilizing fog computing for wearable ECGs, achieved a very high success rate in event detection and sustained battery operation for up to a full week without recharging.
Synapse has enriched 10 related papers. Consider them for comparative context: