Key result
Second CoreValve implantation for significant residual aortic regurgitation following TAVR achieved adequate reduction in AR in 55% of patients, with no peri-procedural stroke or mortality.
Why the study?
Does a second CoreValve implantation reduce residual significant aortic regurgitation in TAVR patients?
Cohort (n=172)
Does a second CoreValve implantation reduce residual significant aortic regurgitation in TAVR patients?
A second self-expanding valve implantation is a safe and effective option to reduce significant residual aortic regurgitation after initial TAVR.
Answers are grounded in this paper and cite their sources.
Second CoreValve implantation may safely reduce residual AR in select TAVR cases; observational data leave open need for randomized confirmation.
BACKGROUND: Residual aortic regurgitation (AR) following transcatheter aortic valve replacement (TAVR) is associated with adverse outcome. We sought to evaluate the efficacy and safety of second CoreValve (CV) implantation to treat residual AR following the initial CV deployment. METHODS AND RESULTS: TAVR patients treated with a second CV due to moderate and above residual AR were compared to single device implantation. Valvular function parameters were compared at baseline, post procedure, and 30 days. Among 172 CV TAVR patients, 11 required a second device (6%) due to significant residual AR. The main differences between the groups were higher rates of low ejection fraction in patients with 2 CV implanted and higher annular diameter (27 [29-25] vs. 25 [26-24] mm, P = 0.03), requiring a larger device. Although two patients in the two CV group had high initial implantation, low implantation was similar between the groups. A second CV achieved adequate reduction in residual AR in six patients (55%), while an additional four patients had moderate residual AR. Only one remained with moderate to severe AR after 30 days follow-up. There were no cases of peri-procedural stroke or mortality. CONCLUSIONS: Second implantation of self-expanding valve can successfully reduce residual significant AR following initial CV implantation and should be considered as therapeutic option for this population.
No takes yet. Share an insight, caveat, or question.
Koifman et al. (2017) conducted a cohort in Residual aortic regurgitation following TAVR (n=172). Second CoreValve implantation vs. Single CoreValve implantation was evaluated on Adequate reduction in residual aortic regurgitation. Second CoreValve implantation for significant residual aortic regurgitation following TAVR achieved adequate reduction in AR in 55% of patients, with no peri-procedural stroke or mortality.
Synapse has enriched 10 related papers. Consider them for comparative context: