Key result
Synchronous computation of CAG-FFR and CAG-IMR yields ~95% diagnostic accuracy versus wire-based FFR and IMR.
Why the study?
Synchronous computation of CAG-FFR and CAG-IMR is a novel angiography-based method, but its diagnostic performance needed validation against wire-based FFR and IMR in suspected myocardial ischemia.
Does coronary angiography-derived FFR and IMR accurately diagnose suspected myocardial ischemia compared to wire-based FFR and IMR in patients with coronary artery disease?
Observational (n=325)
Yes
Does coronary angiography-derived FFR and IMR accurately diagnose suspected myocardial ischemia compared to wire-based FFR and IMR in patients with coronary artery disease?
Angiography-derived FFR and IMR provide excellent diagnostic accuracy for assessing myocardial ischemia and microvascular dysfunction without the need for invasive pressure wires.
Answers are grounded in this paper and cite their sources.
May support wire-free assessment of ischemia and microvascular dysfunction; leaves open randomized outcome trials before clinical adoption.
Background: Synchronous computation of coronary angiography-derived fractional flow reserve (CAG-FFR) and coronary angiography-derived index of microcirculatory resistance (CAG-IMR) is a novel coronary angiography-based method for on-site assessment of suspected myocardial ischemia in patients with coronary artery disease (CAD). Methods: This trial is a prospective, multicenter, controlled study designed to assess the diagnostic performance of CAG-FFR and CAG-IMR in patients with suspected myocardial ischemia using wire-based FFR and IMR as reference standards. The functional parameters were calculated using a reduced order computational fluid dynamics solver that incorporates thrombolysis in myocardial infarction (TIMI) frame count and aortic pressure recorded by a disposable invasive pressure sensor. Results: CAG-FFR was computed in 325 patients, demonstrating a patient-level diagnostic accuracy of 95.4%, sensitivity of 95.9%, and specificity of 95.1%. The area under the receiver operating characteristic curve (AUC) of CAG-FFR was 0.977. Patient-specific aortic pressure adoption significantly improved the accuracy of CAG-FFR in the “gray zone” compared to fixed-pressure models. In addition, CAG-IMR was successfully computed in 180 patients, showing a patient-level diagnostic accuracy of 95.5%, sensitivity of 96.4%, and specificity of 95.2%. The AUC of CAG-IMR in diagnosing abnormal coronary microcirculatory dysfunction was 0.973. Conclusions: Synchronous computation of CAG-FFR and CAG-IMR demonstrated higher feasibility and excellent diagnostic accuracy compared to wire-based FFR and IMR, highlighting its clinical potential for CAD evaluation.
No takes yet. Share an insight, caveat, or question.
Xu et al. (2025) conducted an observational in Suspected myocardial ischemia in patients with coronary artery disease (CAD) (n=325). Coronary angiography-derived fractional flow reserve (CAG-FFR) and index of microcirculatory resistance (CAG-IMR) vs. Wire-based FFR and IMR was evaluated on Diagnostic accuracy of CAG-FFR (AUC 0.977). Synchronous computation of CAG-FFR and CAG-IMR demonstrated excellent diagnostic accuracy and high AUCs compared to wire-based FFR and IMR.