Key result
Custom tapered-fiber sensor detects whole-blood factor Xa activity and therapeutic enoxaparin in under an hour.
Why the study?
Measuring factor Xa activity directly in whole blood could enable point-of-care monitoring and personalized anticoagulant dosing, potentially reducing bleeding risk and related complications.
Does a custom FRET-pair labeled DNA-peptide substrate tethered to a tapered-fiber sensor enable direct optical detection of factor Xa activity in minimally processed whole blood?
Does a custom FRET-pair labeled DNA-peptide substrate tethered to a tapered-fiber sensor enable direct optical detection of factor Xa activity in minimally processed whole blood?
A novel tapered-fiber sensor using a FRET-pair labeled DNA-peptide substrate enables rapid, direct optical detection of factor Xa activity and enoxaparin levels in minimally processed whole blood, offering potential for point-of-care anticoagulant monitoring.
May support preclinical optical FXa monitoring in whole blood; leaves open translation to human point-of-care use.
The ability to measure factor Xa activity directly in whole blood samples offers a path toward point-of-care monitoring and personalized anticoagulant dosage, potentially reducing bleeding risk and other anticoagulant-associated complications. We present a strategy to enable direct optical detection of factor Xa in minimally processed whole blood samples. Our strategy relies on a custom FRET-pair labeled DNA-peptide substrate, allowing FRET ratio to be monitored as an indicator of factor Xa activity. Substrates are tethered to a tapered-fiber sensor to allow evanescent detection of fluorescence directly at the sensor surface, minimizing background media interference and enabling detection directly in blood samples. After characterizing the custom substrate and demonstrating the correlation of fiber-based measurements to an existing chromogenic assay, we demonstrate the detection of endogenous factor Xa activity in >85% whole blood. Finally, we demonstrate the detection of therapeutic concentrations of enoxaparin, a widely used anticoagulant, directly in 90% whole blood in less than an hour and correlate these measurements to activated partial thromboplastin time (aPTT) testing. Together, these results indicate a promising strategy to achieve point-of-care factor Xa detection, enabling personalized anticoagulant treatment and reducing adverse outcomes.
No takes yet. Share an insight, caveat, or question.
Cartwright et al. (2025) studied Anticoagulant monitoring. Direct optical detection of factor Xa using a tapered-fiber sensor vs. Chromogenic assay and aPTT testing was evaluated on Detection of endogenous factor Xa activity and therapeutic concentrations of enoxaparin in whole blood. A custom FRET-pair labeled DNA-peptide substrate on a tapered-fiber sensor enabled direct optical detection of factor Xa activity and therapeutic enoxaparin concentrations in whole blood in under an hour.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: