Key result
Following CoCr-EES implantation, 8-month restenosis rates were 4.4% in-stent, 3.0% at the proximal edge, and 1.1% at the distal edge, with postprocedural % diameter stenosis as a major predictor.
Why the study?
While edge restenosis was a known issue with first-generation DES, the incidence and predictors of edge restenosis after second-generation DES implantation remained to be assessed.
Does postprocedural residual stenosis predict angiographic edge restenosis after second-generation drug-eluting stent implantation?
Observational (n=1,687)
Yes
Does postprocedural residual stenosis predict angiographic edge restenosis after second-generation drug-eluting stent implantation?
Postprocedural percent diameter stenosis is a major independent predictor of edge restenosis after second-generation drug-eluting stent implantation, emphasizing the importance of optimal stent expansion and full lesion coverage.
Answers are grounded in this paper and cite their sources.
May warrant minimizing residual stenosis after CoCr-EES; hypothesis-generating for edge restenosis predictors in observational data.
Edge restenosis has gained attention as a main cause of restenosis after first-generation drug-eluting stent (DES) implantation. The aim of this study was to assess the incidence of edge restenosis and identify the predictors of edge restenosis after second-generation DES implantation. Data were obtained from several postmarketing surveillance (PMS) studies on a cobalt-chromium everolimus-eluting stent (CoCr-EES; Xience V/PROMUS, Xience Prime, Xience Prime SV, and Xience Expedition SV), a second-generation DES, in Japan. Angiographic analysis was conducted at the baseline and after eight months on the following subsegments: in-stent region, proximal edge, and distal edge. Restenosis was defined as ≥ 50% diameter stenosis (DS) at follow-up. We used multivariate logistic regression (with lesions as a random effect) to compare the instances of restenosis between the proximal and the distal edges. Univariate and multivariate analyses of the risk factors for restenosis were performed for each subsegment. We analyzed 1,966 lesions in 1,687 patients. The restenosis rates at the in-stent region, proximal edge, and distal edge were 4.4%, 3.0%, and 1.1%, respectively. The risk of restenosis at the distal edge was significantly lower than that at the proximal edge, when adjusted for 13 variables. The predictors of restenosis were postprocedural % diameter stenosis (%DS), postprocedural reference diameter, ≥ 45° bending, stent overlap at the proximal edge, and postprocedural %DS at the distal edge. Our analysis of eight-month angiographic outcomes from CoCr-EES PMS demonstrated that postprocedural %DS is a major predictor of edge restenosis. Edge restenosis is more likely attributable to postprocedural angiographic results than to the patient's background.
No takes yet. Share an insight, caveat, or question.
Kozuma et al. (2019) conducted an observational in Coronary artery disease requiring stent implantation (n=1,687). Cobalt-chromium everolimus-eluting stent (CoCr-EES) was evaluated on Restenosis (≥ 50% diameter stenosis) at 8 months. Following CoCr-EES implantation, 8-month restenosis rates were 4.4% in-stent, 3.0% at the proximal edge, and 1.1% at the distal edge, with postprocedural % diameter stenosis as a major predictor.