Oral cavity acoustic sensors improve SNR and respiratory rate accuracy over headgear placement.
Why the study?
Respiratory metrics commonly used in lab-based tests have yet to be implemented in contact sports involving physical impact.
Does oral placement of an acoustic sensor improve signal-to-noise ratio and respiratory rate estimation accuracy compared to head placement in sports gear?
Does oral placement of an acoustic sensor improve signal-to-noise ratio and respiratory rate estimation accuracy compared to head placement in sports gear?
p-value: p=1.72 x 10^-6
An oral cavity-based acoustic sensor (smart mouthguard) provides superior signal-to-noise ratio and respiratory rate estimation accuracy compared to headgear placement for field-based sports monitoring.
Oral sensors may improve athlete respiratory monitoring; leaves open larger validation trials before practice change.
Respiratory rate has been identified as a promising metric for field-based sports monitoring. While respiratory metrics, such as minute ventilation are commonly used in lab-based metabolic tests, they have yet to be implemented in contact sports which encounter physical impact. This letter proposes that breathing can be captured on-field via acoustic sensors embedded inside existing sports gear. Two suitable locations for such a system have been identified, either as a smart mouthguard or an instrumented headgear. The signal-to-noise ratio (SNR) at these placements and their potential for respiratory rate estimation will be compared in this letter. Four participants were recruited, and respiratory data were captured in both indoor and outdoor settings. A fast Fourier transform (FFT)-based frequency domain analysis was used to estimate the respiratory rate and determine the breathing rate accuracy. A Wilcoxon signed-rank test was carried out to compare the datasets from the two sensor placements. It was found that the SNR of the oral placement is significantly better than the head placement for both indoor and outdoor settings (indoor: <tex-math notation="LaTeX">P = 5.73 × 10⁻⁷, z = 5</tex-math> ; outdoor: <tex-math notation="LaTeX">P = 2.12 × 10⁻⁷, z = 5.19</tex-math> ). It was also found that the oral placement had a significantly smaller error compared to the head location when predicting respiratory rate (indoor: <tex-math notation="LaTeX">P = 1.72 × 10⁻⁶, z = -4.78</tex-math> ; outdoor: <tex-math notation="LaTeX">P = 1.06 × 10⁻⁷, z = 5.32</tex-math> ). In addition, a convolutional neural network-based classifier was trained to clean up any nonrespiratory sounds from recorded audio, which subsequently achieved a 90% test accuracy. This shows a promising result for demonstrating the viability of a fully automated oral-based respiratory rate monitoring system.
No takes yet. Share an insight, caveat, or question.
Cheng et al. (2023) reported a letter. Oral cavity-based acoustic sensor (smart mouthguard) vs. Instrumented headgear sensor was evaluated on Signal-to-noise ratio (SNR) and respiratory rate estimation error (p=1.72 x 10^-6). An oral cavity-based acoustic sensor demonstrated significantly better signal-to-noise ratio and smaller respiratory rate prediction error compared to headgear placement (indoor error P=1.72x10^-6).