Key result
A semi-automated method quantifying aortic regurgitation via time-density changes on contrast aortography highly correlated with visual grading (r=0.81-0.83, p<0.001) with high inter-observer agreement.
Why the study?
Does semi-automated quantification of aortic regurgitation using time-density curves improve inter-observer reproducibility compared to visual grading after TAVI?
Observational (n=76)
Yes
Does semi-automated quantification of aortic regurgitation using time-density curves improve inter-observer reproducibility compared to visual grading after TAVI?
Effect estimate: r=0.81 and 0.83
p-value: p=<0.001
A novel semi-automated method using time-density changes on contrast aortography provides highly reproducible quantification of aortic regurgitation after TAVI, outperforming standard visual grading.
May support reproducible post-TAVI AR quantification; leaves open superiority to visual grading pending prospective validation.
AIMS: We describe a new semi-automated method that measures aortic regurgitation (AR) on contrast aortography with the objectives of reducing the inter-observer variability and standardising image acquisition. METHODS AND RESULTS: Aortograms from three participating centres were reviewed to generate the following quality criteria: entire left ventricle and aortic root in view, descending aorta or TOE probe not over-projected, breath hold, no table motion, and adequate contrast opacification of the aortic root. AR was visually graded (Sellers) and was quantified by measuring the area under time-contrast density curves in the aortic root (reference) and the left ventricle. Quality criteria were met in 44 retrospectively identified aortograms and in 22 (69%) of 32 prospectively collected aortograms. The visual AR grade (Sellers) was highly correlated with time-density measurements including relative area under the curve (RAUC) and qRA index (r=0.81 and 0.83, respectively, p<0.001). Inter-observer reproducibility of visual grading was moderate (kappa 0.47-0.60, p<0.001). Inter-observer measurement of RAUC and qRA index were highly correlated (r=0.98, p<0.001) and showed a high level of agreement. CONCLUSIONS: Quantification of aortic regurgitation by measurement of time-density changes on contrast aortography may improve the reproducibility of AR assessment in the catheter laboratory. Steps for standardised aortography acquisition are proposed.
No takes yet. Share an insight, caveat, or question.
Schultz et al. (2014) conducted an observational in Aortic regurgitation after TAVI (n=76). Semi-automated time-contrast density curve measurement (RAUC and qRA index) vs. Visual grading (Sellers) was evaluated on Correlation between visual AR grade and time-density measurements (RAUC and qRA index) (r=0.81 and 0.83, p=<0.001). A semi-automated method quantifying aortic regurgitation via time-density changes on contrast aortography highly correlated with visual grading (r=0.81-0.83, p<0.001) with high inter-observer agreement.