Key result
Speckle-tracking echo outperforms conventional echo for sensitive myocardial assessment during mechanical ventilation and MCS.
Why the study?
The potential application of speckle-tracking echocardiography within critical care settings, particularly in patients under mechanical ventilation and mechanical circulatory support, has not yet been fully realized.
Does speckle-tracking echocardiography provide a more sensitive assessment of myocardial function compared to conventional 2D echocardiography in patients under mechanical ventilation and mechanical circulatory support?
Does speckle-tracking echocardiography provide a more sensitive assessment of myocardial function compared to conventional 2D echocardiography in patients under mechanical ventilation and mechanical circulatory support?
Speckle-tracking echocardiography may serve as a more sensitive and reproducible tool than conventional 2D echocardiography for assessing myocardial function in critically ill patients on mechanical ventilation or circulatory support.
Answers are grounded in this paper and cite their sources.
May support speckle-tracking echocardiography in ventilated patients on support; leaves open prospective validation before practice change.
This narrative review aims to discuss the potential applicability of speckle-tracking echocardiography (STE) in patients under mechanical ventilation (MV) and mechanical circulatory support (MCS). Both its benefits and limitations were considered through critical analyses of the current available evidence. DATA SOURCES AND STUDY SELECTION: A literature search was conducted in PubMed and Excerpta Medica Database indexed databases (2012-2021). In addition, the reference lists of all selected studies were manually scanned for further identification of potentially relevant studies. DATA EXTRACTION: The terms "Speckle-Tracking Echocardiography," "Mechanical Ventilation," "Mechanical Circulatory Support," "Extracorporeal Membrane Oxygenation," "Ventricular Assist Devices," and "Left Ventricular Unloading Devices" were searched for the identification of relevant articles for narrative synthesis. DATA SYNTHESIS: STE is a well-established post-processing method of analyzing myocardial function, with potentially greater clinical utility than conventional 2D echocardiography. STE has been incorporated into the guideline recommendations for both the diagnostic and prognostic evaluations of myocardial and valvular pathologies. However, the potential of STE application within critical care settings has not yet been fully realized. Its utility in the assessment of patients undergoing MV and MCS is substantial. Specifically, it may serve as an ideal modality in the assessment of subtle changes in cardiac function. In the limited number of studies reviewed, STE was consistently a more sensitive marker of myocardial functional change, compared with traditional markers of 2D and Doppler parameters during changes in MV and MCS. CONCLUSIONS: Although current evidence is extremely limited, STE strain is suggested to be a more sensitive and reproducible parameter of myocardial function than conventional echocardiographic parameters and may have value in the assessment of patients undergoing MV and MCS in critical care settings. Further studies in larger populations are required to elucidate STE's prognostic capability and its value as a point-of-care tool in guiding clinical practice for subjects under MV and MCS.
No takes yet. Share an insight, caveat, or question.
Sato et al. (2022) conducted a review in Mechanical ventilation and mechanical circulatory support. Speckle-tracking echocardiography (STE) vs. Conventional 2D echocardiography was evaluated. Speckle-tracking echocardiography provides a more sensitive and reproducible assessment of myocardial function compared to conventional echocardiography in patients undergoing mechanical ventilation and circulatory support.
Synapse has enriched 10 related papers. Consider them for comparative context: