April 8, 2022Journal of NeuroInterventional Surgery19 citationsOpen Access

Evaluation of time-resolved whole brain flat panel detector perfusion imaging using RAPID ANGIO in patients with acute stroke: comparison with CT perfusion imaging

View Full Paper
CKChristoph C. KurmannUniversity of BernJKJohannes KaesmacherUniversity of BernDCDaniel L. CookeCity College of San Francisco

Key Points

Key points are not available for this paper at this time.

Abstract

Background In contrast to conventional CT perfusion (CTP) imaging, flat panel detector CT perfusion (FD-CTP) imaging can be acquired directly in the angiosuite. Objective To evaluate time-resolved whole brain FD-CTP imaging and assess clinically important qualitative and quantitative perfusion parameters in correlation with previously acquired conventional CTP using the new RAPID for ANGIO software. Methods We included patients with internal carotid artery occlusions and M1 or M2 occlusions from six centers. All patients underwent mechanical thrombectomy (MT) with preinterventional conventional CTP and FD-CTP imaging. Quantitative performance was determined by comparing volumes of infarct core, penumbral tissue, and mismatch. Eligibility for MT according to the perfusion imaging criteria of DEFUSE 3 was determined for each case from both conventional CTP and FD-CTP imaging. Results A total of 20 patients were included in the final analysis. Conventional relative cerebral blood flow (rCBF) 6 s versus FD-CTP Tmax >6 s and CTP mismatch versus FD-CTP mismatch showed more variability (R 2 =0.57, and R 2 =0.33, respectively). Based on FD-CTP, 16/20 (80%) patients met the inclusion criteria for MT according to the DEFUSE 3 perfusion criteria, in contrast to 18/20 (90%) patients based on conventional CTP. The vessel occlusion could be correctly extrapolated from the hypoperfusion in 18/20 cases (90%). Conclusions In our multicenter study, time-resolved whole brain FD-CTP was technically feasible, and qualitative and quantitative perfusion results correlated with those obtained with conventional CTP.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Kurmann et al. (2022) studied this question.

synapsesocial.com/papers/6a1539d9a2352da347821874https://doi.org/10.1136/neurintsurg-2021-018464
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Improving mTICI2b reperfusion to mTICI2c/3 reperfusions: A retrospective observational study assessing technical feasibility, safety and clinical efficacy2017 · 75 citations
  2. 2Perfusion-CT Assessment of Infarct Core and Penumbra2006 · 772 citations
  3. 3CT perfusion improves diagnostic accuracy and confidence in acute ischaemic stroke2013 · 108 citations
  4. 4European Stroke Organisation (ESO)- European Society for Minimally Invasive Neurological Therapy (ESMINT) guidelines on mechanical thrombectomy in acute ischemic stroke2019 · 475 citations
  5. 5Diagnostic accuracy of flat-panel computed tomography in assessing cerebral perfusion in comparison with perfusion computed tomography and perfusion magnetic resonance: a systematic review2019 · 11 citations