Answers are grounded in this paper and cite their sources.
Voltage regulation schemes for current-source inverters (CSIs) commonly use a simple proportional-integral (PI) stationary frame controller, but this approach is known to suffer from significant steady-state error. In contrast, the more advanced schemes that are routinely used for current regulation of voltage-source inverters (VSIs) avoid these problems. This paper presents an approach to directly utilize VSI current regulation strategies to control the voltage for a CSI, without requiring significant modification or development. The approach uses a space-vector mapping technique to convert VSI modulation signals to CSI gate drive signals, which allows VSI closed-loop current control strategies to be directly applied to CSI voltage regulation. Three new voltage regulation CSI controllers based on hysteresis, synchronous frame PI, and stationary frame P+Resonant control principles are presented based on this concept.
No takes yet. Share an insight, caveat, or question.
Zmood et al. (2001) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: