Key result
Lightweight 1D-CNN with hardware acceleration achieves ~99% accuracy for ECG beat classification.
Why the study?
Traditional CNN-based accelerators for ECG beat classification face limitations including large parameter counts, limited configurability, and inefficient hardware utilization.
A lightweight 1D-CNN with a custom hardware accelerator provides highly accurate and efficient ECG beat classification suitable for real-time deployment in resource-constrained environments.
May facilitate real-time ECG monitoring in constrained settings; leaves open prospective clinical validation.
Convolutional Neural Networks (CNNs) have become a dominant solution for Electrocardiogram (ECG) beat classification, owing to their superior feature extraction capabilities. However, traditional CNN-based accelerators often encounter limitations such as large parameter counts, limited configurability, and inefficient hardware utilization. In this work, we propose a lightweight one-dimensional CNN (1D-CNN) inspired by the InceptionNet architecture, specifically designed for efficient and accurate ECG beat classification. The model integrates customized Inception blocks with parallel convolutional layers of varying kernel sizes to capture multi-scale temporal features. To reduce model complexity and enhance efficiency, <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1 × 1</tex> convolutions are used for dimensionality reduction, resulting in a compact network with only 7,740 parameters. Additionally, we present a hardware accelerator that exploits spatial data reuse across multiple processing units and employs dual-port RAM for concurrent data access, improving throughput and memory efficiency. When implemented on hardware with parallel and pipelined execution at 100 MHz, the system achieves a classification accuracy of 99.32%, sensitivity of 98.50%, specificity of 99.58%, and a positive predictive value (PPV) of 98.30% across five ECG classes with the MIT-BIH database, demonstrating its suitability for real-time deployment in resource-constrained environments.
No takes yet. Share an insight, caveat, or question.
Nhat et al. (2025) studied ECG beat classification. Lightweight 1D-CNN (InceptionNet architecture) and hardware accelerator was evaluated on Classification accuracy, sensitivity, specificity, and positive predictive value across five ECG classes. A lightweight 1D-CNN with a hardware accelerator achieved a classification accuracy of 99.32%, sensitivity of 98.50%, and specificity of 99.58% for ECG beat classification.