Key result
A centerline-based model morphing algorithm successfully generated patient-specific finite element models of the left ventricle with marginal mismatches in 8 patients with congestive heart disease.
A novel centerline-based model morphing algorithm enables fast and robust generation of patient-specific finite element models of the left ventricle from ultrasound data.
Answers are grounded in this paper and cite their sources.
Supports feasibility of patient-specific LV finite element modeling from ultrasound; leaves open larger-scale validation before clinical use.
GOAL: Hexahedral automatic model generation is a recurrent problem in computer vision and computational biomechanics. It may even become a challenging problem when one wants to develop a patient-specific finite element (FE) model of the left ventricle (LV), particularly when only low resolution images are available. In the present study, a fast and efficient algorithm is presented and tested to address such a situation. METHODS: A template FE hexahedral model was created for an LV geometry using a general electric ultrasound (US) system. A system of centerline was considered for this LV mesh. Then, the nodes located over the endocardial and epicardial surfaces are, respectively, projected from this centerline onto the actual endocardial and epicardial surfaces reconstructed from a patient's US data. Finally, the position of the internal nodes is derived by finding the deformations with minimal elastic energy. This approach was applied to eight patients suffering from congestive heart disease. An FE analysis was performed to derive the stress induced in the LV tissue by diastolic blood pressure on each of them. RESULTS: Our model morphing algorithm was applied successfully and the obtained meshes showed only marginal mismatches when compared to the corresponding US geometries. The diastolic FE analyses were successfully performed in seven patients to derive the distribution of principal stresses. CONCLUSION: The original model morphing algorithm is fast and robust with low computational cost. SIGNIFICANCE: This low-cost model morphing algorithm may be highly beneficial for future patient-specific reduced-order modeling of the LV with potential application to other crucial organs.
No takes yet. Share an insight, caveat, or question.
Behdadfar et al. (2017) studied Congestive heart disease (n=8). Centerline-based model morphing algorithm was evaluated on Successful application of model morphing algorithm and diastolic FE analysis. A centerline-based model morphing algorithm successfully generated patient-specific finite element models of the left ventricle with marginal mismatches in 8 patients with congestive heart disease.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: