Key result
Top-Hat CarboMedics prosthesis linked to ~7% larger effective orifice area and lower pressure gradients versus standard.
Why the study?
The CarboMedics Top-Hat aortic valve prosthesis was designed for supra-annular implantation, but its hemodynamic performance compared to the standard CarboMedics prosthesis needed evaluation.
Does the CarboMedics Top-Hat aortic valve prosthesis improve effective orifice area and pressure gradient compared to the standard CarboMedics aortic valve prosthesis in patients undergoing aortic valve replacement?
Cohort (n=98)
Does the CarboMedics Top-Hat aortic valve prosthesis improve effective orifice area and pressure gradient compared to the standard CarboMedics aortic valve prosthesis in patients undergoing aortic valve replacement?
The supra-annular Top-Hat CarboMedics aortic valve prosthesis provides superior hemodynamic performance, including larger effective orifice area and lower pressure gradients, compared to the standard CarboMedics valve.
Associated with better hemodynamics in aortic valve replacement; leaves open outcome benefits versus standard prosthesis.
Background: The CarboMedics Top-Hat aortic valve prosthesis was designed to be implanted in a supra-annular position. This study aimed to compare the hemodynamic performance of the Top-Hat aortic prostheses versus the standard CarboMedics aortic valve prostheses. Methods: The study included 98 patients who had aortic valve replacement and were divided into two groups. Group A included 60 patients who had standard aortic valve prostheses, and Group B included 38 patients who had the Top-Hat aortic prostheses. The study endpoints were hospital outcomes, the effective orifice area, and the pressure gradient during a one-year follow-up. Results: There was no significant difference in the baseline echocardiographic data and risk factors between the groups. The patients who had Top-Hat aortic prosthesis were younger, with a mean age of 47.5 (44-55) years, and those who had the standard prosthesis were 53.5 (48-56) years old (P= 0.02). The cardiopulmonary bypass time was significantly less in the Top-Hat prosthesis group with an average of 78 min (75- 81) compared to 88 min (84- 95) in the other group (P ˂0.001). The effective orifice surface area was significantly larger in the group with Top-Hat prosthesis; 0.9 mm/m2 (0.88- 0.92) compared to 0.84 mm/m 2 (0.79- 0.87) for the standard aortic valve prosthesis group (P ˂0.001). The pressure gradient over the aortic valve decreased significantly postoperatively (coefficient -1.98 (-2.21- -1.75); P˂0.001). Patients with Top-Hat valves had significantly lower gradient (coefficient: -4.22 (-6.61- -1.82); P= 0.001), while age had no effect on the pressure gradient (coefficient: 0.1 ( -0.07- 0.27); P= 0.25). Conclusion: The Top-Hat CarboMedics prostheses could be superior to the standard CarboMedics aortic valve prosthesis regarding the effective orifice area and pressure gradient over the valve.
No takes yet. Share an insight, caveat, or question.
Fouly et al. (2022) conducted a cohort in Aortic valve replacement (n=98). CarboMedics Top-Hat aortic valve prosthesis vs. Standard CarboMedics aortic valve prostheses was evaluated on Effective orifice surface area (mm/m2) (p=<0.001). The Top-Hat CarboMedics prosthesis yielded a significantly larger effective orifice area (0.9 vs 0.84 mm/m2; P<0.001) and lower pressure gradient compared to the standard CarboMedics prosthesis.