Key result
Heart rate variability analysis accurately determined the ventilatory threshold during an incremental shuttle walk test, with similar walking speeds at threshold (5.10 vs 5.04 km/h; p=0.89).
Why the study?
Does heart rate variability analysis accurately determine the ventilatory threshold during an incremental shuttle walk test in healthy subjects?
Observational (n=10)
Does heart rate variability analysis accurately determine the ventilatory threshold during an incremental shuttle walk test in healthy subjects?
Absolute Event Rate: 5.1% vs 5.04%
p-value: p=0.89
Heart rate variability analysis using a simple heart monitor can accurately estimate the ventilatory threshold during an incremental shuttle walk test, providing a useful tool for exercise prescription.
May enable simpler threshold estimation in exercise testing; leaves open prospective validation before clinical adoption.
We aimed to examine whether the ventilatory threshold (VT) during an incremental shuttle walk test (ISWT) could be determined using heart rate variability (HRV) analysis. Further aims were to assess variables capable of predicting performance in the ISWT and the intensity of this test. Beat-to-beat RR intervals and gas exchange values in 10 healthy subjects (31-83 years; 7 men) were collected during the ISWT. The ventilatory equivalent was used to assess VT from respiratory components. To determine the HRV threshold (HRVT), the instantaneous beat-to-beat variability values of the RR intervals at each stage of exercise were graphically plotted against walking speed (WS). The oxygen consumption at HRVT was calculated (VO2HRVT). No significant differences were found between walking speed (WS) at VT and WS at HRVT (5.04±1.00 vs. 5.10±1.04 km/h; p=0.89). Linear regression analysis revealed a strong correlation between VO2VT and VO2HRVT (r(2)=0.896). The Bland and Altman plot analysis revealed an agreement between VO2VT and VO2HRVT (-0.05; 95%CI: -0.30-0.20 L/min). Thus, the VT can be assessed during the ISWT using a simple heart monitor. The ISWT may be a useful tool to assess exercise capacity and prescribe walking programs.
No takes yet. Share an insight, caveat, or question.
Dourado et al. (2010) conducted an observational in Healthy (n=10). Heart rate variability (HRV) analysis vs. Ventilatory equivalent (respiratory components) was evaluated on Walking speed at ventilatory threshold (km/h) (p=0.89). Heart rate variability analysis accurately determined the ventilatory threshold during an incremental shuttle walk test, with similar walking speeds at threshold (5.10 vs 5.04 km/h; p=0.89).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: