Key result
Ablation at negative dPPI sites is associated with ~92% higher tachycardia termination rates.
Why the study?
Although dPPI < 30 ms is considered within the re-entry circuit, the clinical importance of post-pacing intervals shorter than tachycardia cycle length (PPI < TCL) as a target for atypical flutter ablation remained to be assessed.
Does targeting ablation sites with a negative dPPI (PPI < TCL) improve tachycardia termination rates in patients undergoing atypical flutter ablation?
Observational (n=177)
Does targeting ablation sites with a negative dPPI (PPI < TCL) improve tachycardia termination rates in patients undergoing atypical flutter ablation?
Targeting ablation sites with a negative dPPI (PPI < TCL) during entrainment mapping is more effective for terminating atypical flutter than targeting sites with dPPI 0-30 ms.
Negative dPPI sites were associated with higher termination in atypical flutter ablation; hypothesis-generating and requires prospective validation.
AIMS: During entrainment mapping of macro-reentrant tachycardias, the time difference (dPPI) between post-pacing interval (PPI) and tachycardia cycle length (TCL) is thought to be a function of the distance of the pacing site to the re-entry circuit and dPPI < 30 ms is considered within the re-entry circuit. This study assessed the importance of PPI < TCL as a successful target for atypical flutter ablation. METHODS AND RESULTS: A total of 177 ablation procedures were investigated. Surface electrocardiograms (ECGs) were evaluated and combined activation and entrainment mapping were performed to choose ablation sites. Each entrainment sequence immediately preceding static radiofrequency delivery at the same site was analysed. A total of 545 entrainment sequences were analysed. dPPI < 0 ms was observed in 45.3% (247/545) sequences. Ablation resulted in tachycardia termination more often at sites with dPPI < 0 (27.8% vs. 14.5%, P < 0.001) and with a progressively increasingly inverse correlation between dPPI duration and ablation success [odds ratio (OR): 0.974; 95% confidence interval (CI) 0.960-0.988; P < 0.001]. Tachycardia termination or cycle length prolongation also occurred more often at sites with dPPI < 0 (50.6% vs. 33.2%, P < 0.001) and with a similar inverse correlation with dPPI duration (OR: 0.972; 95% CI 0.960-0.984; P < 0.001). Twelve-lead synchronous isoelectric intervals were observed in 64.4% (163/253) flutter ECGs and were associated with a dPPI < 0 (75.3% vs. 55.8%, P < 0.001). CONCLUSION: When combined with activation mapping, a negative dPPI is a more effective parameter for identifying a target for successful ablation compared to a dPPI = 0-30 ms. Its occurrence is associated with a critical small narrow slow-conducting isthmus at the target site.
No takes yet. Share an insight, caveat, or question.
Dall’Aglio et al. (2020) conducted an observational in Atypical flutter (n=177). Ablation at sites with dPPI < 0 ms vs. Ablation at sites with dPPI ≥ 0 ms was evaluated on Tachycardia termination (OR 0.974, 95% CI 0.960-0.988, p=<0.001). Catheter ablation at sites with a negative dPPI (PPI < TCL) resulted in higher rates of tachycardia termination compared to sites with dPPI ≥ 0 (27.8% vs. 14.5%, P < 0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: