Key result
The verification phase procedure consistently yielded small, insignificant mean differences in maximal VO2 compared to the incremental phase across six studies.
Why the study?
Does the verification phase procedure better confirm true VO2max compared to traditional criteria?
Does the verification phase procedure better confirm true VO2max compared to traditional criteria?
The verification phase procedure offers an alternative to traditional criteria for confirming true VO2max, though standardized individual criterion thresholds are still needed.
Answers are grounded in this paper and cite their sources.
Verification phase adds little to incremental testing for confirming VO2max; leaves open need for standardized individual criteria in prospective studies.
Traditional (.)VO(2max) criteria are typically based on attainment of a (.)VO2 plateau, and threshold values for the respiratory exchange ratio, heart rate and blood lactate concentration. Despite long-standing criticisms directed at these criteria, their use remains widespread. This article discusses an alternative procedure, termed the verification phase, for confirming the attainment of true (.)VO(2max). Following a continuous incremental exercise test to the limit of tolerance and appropriate recovery period, the verification phase is performed and is characterized by a supramaximal square wave exercise bout. Consistent peak (.)VO2 values in the incremental and verification phases, confirms that a true (.)VO(2max) has been attained. Six recent studies investigated the utility of the verification phase for evaluating true (.)VO(2max). These studies consistently found small insignificant mean differences between the maximal (.)VO2 attained in the incremental and verification phases. However, this group mean approach does not identify individual subjects who may not have attained a true (.)VO(2max). Notably, only one of the six studies reported a criterion threshold to verify the (.)VO(2max) of individual subjects. Further research is required to investigate the utility of different verification phase procedures and to establish a suitable verification criterion threshold for confirming true VO(2max).
No takes yet. Share an insight, caveat, or question.
Midgley et al. (2009) conducted a review in VO2max testing. Verification phase procedure vs. Incremental phase was evaluated on Maximal VO2 difference between incremental and verification phases. The verification phase procedure consistently yielded small, insignificant mean differences in maximal VO2 compared to the incremental phase across six studies.
Synapse has enriched 10 related papers. Consider them for comparative context: