Key result
DIMAC MRI successfully measures real-time pulsatile flow with pulsatility index linked to TR.
Why the study?
Pulsatility of blood flow through cerebral arteries is clinically important and intrinsically associated with cerebrovascular health, prompting the development of a new MRI approach to measure real-time pulsatile flow.
Can dynamic inflow magnitude contrast (DIMAC) MRI accurately measure real-time pulsatile flow in cerebral arteries?
Observational (n=6)
No
Can dynamic inflow magnitude contrast (DIMAC) MRI accurately measure real-time pulsatile flow in cerebral arteries?
p-value: p=0.00062
DIMAC is a novel MRI technique that effectively measures real-time pulsatile flow in cerebral arteries without requiring velocity-encoding gradients.
DIMAC MRI may enable non-contrast pulsatile cerebral flow assessment; leaves open clinical translation pending validation.
The pulsatility of blood flow through cerebral arteries is clinically important, as it is intrinsically associated with cerebrovascular health. In this study we outline a new MRI approach to measuring the real-time pulsatile flow in cerebral arteries, which is based on the inflow phenomenon associated with fast gradient-recalled-echo acquisitions. Unlike traditional phase-contrast techniques, this new method, which we dub dynamic inflow magnitude contrast (DIMAC), does not require velocity-encoding gradients as sensitivity to flow velocity is derived purely from the inflow effect. We achieved this using a highly accelerated single slice EPI acquisition with a very short TR (15 ms) and a 90° flip angle, thus maximizing inflow contrast. We simulate the spoiled GRE signal in the presence of large arteries and perform a sensitivity analysis. The sensitivity analysis demonstrates that in the regime of high inflow contrast, DIMAC shows much greater sensitivity to flow velocity over blood volume changes. We support this theoretical prediction with in-vivo data collected in two separate experiments designed to demonstrate the utility of the DIMAC signal contrast. We perform a hypercapnia challenge experiment in order to experimentally modulate arterial tone within subjects, and thus modulate the arterial pulsatile flow waveform. We also perform a thigh-cuff release challenge, designed to induce a transient drop in blood pressure, and demonstrate that the continuous DIMAC signal captures the complex transient change in the pulsatile and non-pulsatile components of flow. In summary, this study proposes a new role for a well-established source of MR image contrast and demonstrates its potential for measuring both steady-state and dynamic changes in arterial tone.
No takes yet. Share an insight, caveat, or question.
Whittaker et al. (2022) conducted an observational in Healthy participants (n=6). Dynamic inflow magnitude contrast (DIMAC) MRI vs. Longer TR acquisitions (30, 60, 120 ms) was evaluated on Pulsatility index (PI) dependence on TR (p=0.00062). Dynamic inflow magnitude contrast (DIMAC) MRI using a short TR (15 ms) and 90° flip angle successfully measured real-time pulsatile flow, with pulsatility index significantly dependent on TR (p=0.00062).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: