Key result
DIMAC MRI captures transient beat-to-beat pulsatile cerebral blood flow changes during physiological challenges.
Why the study?
Blood flow pulsatility through cerebral arteries is clinically important and associated with cerebrovascular health, prompting the development of a new MRI approach to measure real-time pulsatile flow.
DIMAC is a novel MRI method that exploits the inflow effect on fast GRE imaging to measure dynamic, beat-to-beat pulsatile flow in cerebral arteries without requiring velocity-encoding gradients.
DIMAC MRI may enable noninvasive beat-to-beat cerebral flow assessment; leaves open validation before clinical use.
The pulsatility of blood flow through cerebral arteries is clinically important, as it is intrinsically associated with cerebrovascular health. In this study we outline a new MRI approach to measuring the real-time pulsatile flow in cerebral arteries, which is based on the inflow phenomenon associated with fast gradient-recalled-echo acquisitions. Unlike traditional phase-contrast techniques, this new method, which we dub D ynamic I nflow Ma gnitude C ontrast (DIMAC), does not require velocity-encoding gradients as sensitivity to flow velocity is derived purely from the inflow effect. We achieved this using a highly accelerated single slice EPI acquisition with a very short TR (15 ms) and a 90° flip angle, thus maximizing inflow contrast. We simulate the spoiled GRE signal in the presence of large arteries and perform a sensitivity analysis to demonstrate that in the regime of high inflow contrast it shows much greater sensitivity to flow velocity over blood volume changes. We support this theoretical prediction with in-vivo data collected in two separate experiments designed to demonstrate the utility of the DIMAC signal contrast. We perform a hypercapnia challenge experiment in order to experimentally modulate arterial tone within subjects, and thus modulate the arterial pulsatile flow waveform. We also perform a thigh-cuff release challenge, designed to induce a transient drop in blood pressure, and demonstrate that the continuous DIMAC signal captures the complex transient change in the pulsatile and non-pulsatile components of flow. In summary, this study proposes a new role for a well-established source of MR image contrast and demonstrates its potential for measuring both steady-state and dynamic changes in arterial tone. Highlights We present a novel method for measuring pulsatility of cerebral arteries. The inflow effect on fast GRE imaging can be exploited to yield a flow velocity dependent signal. We measure pulsatile flow through cerebral arteries dynamically on a beat-to-beat basis. We use physiological challenges to demonstrate sensitivity to dynamic and steady-state changes in vascular tone.
No takes yet. Share an insight, caveat, or question.
Whittaker et al. (2021) studied Cerebrovascular health. Dynamic Inflow MAgnitude Contrast (DIMAC) MRI was evaluated on Real-time pulsatile flow in cerebral arteries. Dynamic Inflow MAgnitude Contrast (DIMAC) MRI (TR 15 ms, 90° flip angle) successfully captured transient changes in beat-to-beat pulsatile cerebral blood flow during physiological challenges.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: