Key result
Post-ablation sinus heart rate change under 11 bpm predicts ~82% higher atrial tachyarrhythmia recurrence.
Why the study?
Catheter ablation is known to influence the autonomic nervous system, but the association of sinus heart rate pre- and post-ablation with recurrences after pulmonary vein isolation remained to be clarified.
Does a sinus heart rate change < 11 bpm predict atrial tachyarrhythmia recurrences in patients with atrial fibrillation undergoing pulmonary vein isolation?
Cohort (n=482)
No
Does a sinus heart rate change < 11 bpm predict atrial tachyarrhythmia recurrences in patients with atrial fibrillation undergoing pulmonary vein isolation?
A sinus heart rate increase of less than 11 bpm from pre-ablation to 3 months post-ablation is associated with a higher risk of atrial tachyarrhythmia recurrence after pulmonary vein isolation.
Should not yet guide post-PVI monitoring; leaves open whether sinus rate change independently predicts recurrence after multivariable adjustment.
PURPOSE: Cather ablation is known to influence the autonomic nervous system. This study sought to investigate the association of sinus heart rate pre-/post-ablation and recurrences in patients with atrial fibrillation undergoing pulmonary vein isolation (PVI). METHODS: Between January 2012 and December 2017, data of 482 patients undergoing their first PVI were included. Sinus heart rate was recorded before (PRE), directly post-ablation (POST) and 3 months post-ablation (3 M). All patients were screened for atrial tachyarrhythmia recurrences during the one-year follow-up. RESULTS: In the total study cohort, the mean resting sinus heart rate at PRE [mean 57.9 bpm (95% CI 57.1-58.7 bpm)] increased by over 10 bpm to POST [mean 69.4 bpm (95% CI 68.5-70.3 bpm); p < 0.001] followed by a slight decrease at 3 M [mean 67.3 bpm (95% CI 66.4-68.2 bpm)] but still remaining higher compared to PRE (p < 0.001). This pattern was observed in patients with and without recurrences at POST and 3 M (both p < 0.001 compared to PRE). However, at 3 M the mean sinus heart rate was significantly lower in patients with compared to patients without recurrences (p = 0.031). In this regard, patients with a heart rate change < 11 bpm (PRE to 3 M) or, as an alternative parameter, patients with a heart rate < 60 bpm at 3 M had a significantly higher risk of recurrences compared to the remaining patients (Hazard ratio (HR) 1.82 (95% CI 1.32-2.49), p < 0.001 and HR 1.64 (95% CI 1.20-2.25), p = 0.002, respectively). CONCLUSION: Our study confirms the impact of PVI on cardiac autonomic function with a significant sinus heart rate increase post-ablation. Patients with a sinus heart rate change < 11 bpm (PRE to 3 M) are at higher risk for recurrences during one-year post-PVI.
No takes yet. Share an insight, caveat, or question.
Olshausen et al. (2020) conducted a cohort in Atrial fibrillation (n=482). Sinus heart rate change < 11 bpm (PRE to 3 months post-PVI) vs. Sinus heart rate change ≥ 11 bpm (PRE to 3 months post-PVI) was evaluated on Recurrence of atrial tachyarrhythmia (HR 1.82, 95% CI 1.32-2.49, p=<0.001). Patients with a sinus heart rate change of less than 11 bpm from pre-ablation to 3 months post-ablation had a significantly higher risk of atrial tachyarrhythmia recurrences (HR 1.82).