Key result
Exercise potassium-43 myocardial perfusion scans show normal distribution in 100% of false-positive exercise tests.
Why the study?
False-positive ECG exercise tests with ischemic responses occur in patients without clinical coronary heart disease, and noninvasive methods to accurately assess these patients are needed.
Does exercise potassium-43 myocardial perfusion imaging accurately assess patients with suspected false-positive exercise tests?
Observational (n=12)
Does exercise potassium-43 myocardial perfusion imaging accurately assess patients with suspected false-positive exercise tests?
Potassium-43 exercise myocardial perfusion scanning provides an accurate noninvasive method to identify false-positive exercise tests, thereby increasing the specificity of exercise testing.
Answers are grounded in this paper and cite their sources.
May support potassium-43 imaging to identify false-positive exercise tests; leaves open validation in larger studies.
Twelve patients with false-positive ECG exercise tests presented with ischemic ECG responses (greater than one mm ST segment depression) during graded maximal treadmill exercise testing in the absence of exercise-induced chest pain or clinical coronary heart disease. Coronary arteriography, left ventriculography and hemodynamic evaluation revealed no significant abnormality in these patients. Transmyocardial lactate analysis during atrial pacing revealed a normal extraction (mean 21%) during pacing stress in five patients. Nine of 12 patients were evaluated with exercise potassium-43 myocardial perfusion imaging whereby the radioactive tracer was administered intravenously during exercise at a time when abnormal ECG changes were present. Myocardial images in these nine patients all showed a normal homogeneous pattern of radioisotope distribution. These results are in direct contrast to findings in patients with coronary heart disease in whom reproducibly demonstrable abnormal regions of decreased potassium-43 accumulation have been noted in myocardial images obtained following injection of the radioactive tracer during exercise. Potassium-43 exercise myocardial perfusion scanning thus appears to be an accurate noninvasive method of assessing patients with suspected false-positive exercise tests and provides a means of increasing the specificity of exercise testing.
No takes yet. Share an insight, caveat, or question.
Zaret et al. (1973) conducted an observational in False-positive ECG exercise tests (n=12). Potassium-43 myocardial perfusion scanning was evaluated on Myocardial radioisotope distribution pattern. Exercise potassium-43 myocardial perfusion scanning showed a normal homogeneous pattern of radioisotope distribution in all 9 evaluated patients with false-positive ECG exercise tests.
Synapse has enriched 10 related papers. Consider them for comparative context: