Key result
Radiofrequency ablation of the slow pathway in AVNRT elicited junctional beats at a mean temperature of 45.4°C, while successful ablation required maximum temperatures ranging from 45 to 88°C.
Why the study?
What is the temperature response of the slow atrioventricular nodal pathway during radiofrequency ablation in patients with AVNRT?
Observational (n=23)
What is the temperature response of the slow atrioventricular nodal pathway during radiofrequency ablation in patients with AVNRT?
The slow AV nodal pathway responds to heat at approximately 45.4°C, but the temperature required for successful ablation varies widely among patients.
Answers are grounded in this paper and cite their sources.
Variability in ablation temperatures cautions against uniform protocols in AVNRT; leaves open optimal targets pending larger prospective data.
The present study attempted to determine the lowest temperature at which the slow atrioventricular nodal pathway responds to heating and the temperature necessary for successful ablation of the slow pathway in patients with atrioventricular nodal reentrant tachycardia (AVNRT). The study group comprised 23 consecutive patients (14 women, 9 men) with symptomatic AVNRT. Radiofrequency current was delivered at the slow pathway potential recording site using a HAT 200S catheter ablation system. Successful radiofrequency ablation of the slow pathway was achieved in all 23 patients. Junctional beats, suggesting the response of the slow pathway to temperature, were detected in 62 of the total 136 applications. The temperature measured at the first junctional beat was 45.4+/-4.2 degrees C. The maximum temperature required for the successful ablation of AVNRT ranged from 45 to 88 degrees C. There were no complications except for 1 patient with transient atrioventricular (AV) block. There were no recurrences of AVNRT during follow-up. The lowest temperature at which the slow pathway was responsive to heat was quite similar to that for accessory pathways or the AV junction. However, the temperature required for the successful ablation of AVNRT differed markedly among the patients.
No takes yet. Share an insight, caveat, or question.
Kawabata et al. (1999) conducted an observational in Atrioventricular nodal reentrant tachycardia (AVNRT) (n=23). Radiofrequency catheter ablation was evaluated on Lowest temperature at which the slow pathway responds to heating and temperature necessary for successful ablation. Radiofrequency ablation of the slow pathway in AVNRT elicited junctional beats at a mean temperature of 45.4°C, while successful ablation required maximum temperatures ranging from 45 to 88°C.
Synapse has enriched 10 related papers. Consider them for comparative context: