Key result
Published 12-lead ECG algorithms to localize AV accessory pathways had significantly lower positive predictive values when using >6 location sites (40.6% vs 61.2%; P<0.03).
Why the study?
How accurate are published 12-lead ECG algorithms in localizing overt AV accessory pathways compared to successful ablation sites?
Observational (n=266)
How accurate are published 12-lead ECG algorithms in localizing overt AV accessory pathways compared to successful ablation sites?
The accuracy of 12-lead ECG algorithms for localizing accessory pathways is limited, particularly for algorithms defining more than 6 sites or those not incorporating delta wave polarity.
Algorithms with >6 sites warrant caution in clinical localization; leaves open whether simplified algorithms improve ablation guidance.
INTRODUCTION: The purpose of this study was to evaluate the accuracy and limitations of published algorithms using the 12-lead ECG to localize AV accessory pathways (APs). METHODS AND RESULTS: The 11 relevant algorithms found in the literature (MEDLINE database and major scientific sessions) were tested on a series of 266 consecutive patients who successfully underwent radiofrequency catheter ablation of a single overt AV AP. The positive predictive values (PPV) of the algorithms in applicable patients were significantly lower for algorithms with > 6 accessory location sites (40.6% +/- 10.9% vs 61.2% +/- 8.0%; P < 0.03) and show a tendency for algorithms not relying on delta wave polarity but on QRS polarity only (36.6% +/- 11.2% vs 52.3% +/- 13.1%; P = 0.09). The PPV in applicable patients is related to the AP location (P < 0.001) and ranked from the highest to the lowest as follows: left lateral (mean PPV = 86.3%), posteroseptal (mean PPV = 65.2%), right anteroseptal (mean PPV = 45.2%), and right posterolateral (mean PPV = 23.4%). CONCLUSION: Our study suggests that the accuracy of algorithms relying on the 12-lead ECG depends on AP locations as defined in the algorithms and on the number of AP sites. The accuracy tends to be lower when delta wave polarity is not included in the algorithm's architecture. This should be considered when using these algorithms or when building new ones.
No takes yet. Share an insight, caveat, or question.
Basiouny et al. (1999) conducted an observational in Overt atrioventricular accessory pathways (n=266). 12-lead ECG algorithms was evaluated on Positive predictive value (PPV) of the algorithms (p=<0.03). Published 12-lead ECG algorithms to localize AV accessory pathways had significantly lower positive predictive values when using >6 location sites (40.6% vs 61.2%; P<0.03).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: