Key result
Voltage-sensitive fluorescent dyes provided an accurate method to assess hiPSC-CM electrophysiology, detecting significant differences in APD90 between Cor.4U (229 ms) and iCell (427 ms) cells.
Why the study?
Does ratiometric fluorescence measurement of voltage-sensitive dye di-4-ANEPPS accurately assess action potential characteristics and drug effects in human induced pluripotent stem cell-derived cardiomyocytes?
Does ratiometric fluorescence measurement of voltage-sensitive dye di-4-ANEPPS accurately assess action potential characteristics and drug effects in human induced pluripotent stem cell-derived cardiomyocytes?
Absolute Event Rate: 229% vs 427%
p-value: p=< 0.01
Voltage-sensitive dyes provide a minimally invasive, quantitative method to assess hiPSC-CM electrophysiology and detect subtle drug-induced effects for drug safety screening.
Enables hiPSC-CM electrophysiology screening; leaves open clinical translation and in vivo validation.
Human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CM) and higher throughput platforms have emerged as potential tools to advance cardiac drug safety screening. This study evaluated the use of high bandwidth photometry applied to voltage-sensitive fluorescent dyes (VSDs) to assess drug-induced changes in action potential characteristics of spontaneously active hiPSC-CM. Human iPSC-CM from 2 commercial sources (Cor.4U and iCell Cardiomyocytes) were stained with the VSD di-4-ANEPPS and placed in a specialized photometry system that simultaneously monitors 2 wavebands of emitted fluorescence, allowing ratiometric measurement of membrane voltage. Signals were acquired at 10 kHz and analyzed using custom software. Action potential duration (APD) values were normally distributed in cardiomyocytes (CMC) from both sources though the mean and variance differed significantly (APD90: 229 ± 15 ms vs 427 ± 49 ms [mean ± SD, P < 0.01]; average spontaneous cycle length: 0.99 ± 0.02 s vs 1.47 ± 0.35 s [mean ± SD, P < 0.01], Cor.4U vs iCell CMC, respectively). The 10–90% rise time of the AP (Trise) was ∼6 ms and was normally distributed when expressed as 1/Trise2 in both cell preparations. Both cell types showed a rate dependence analogous to that of adult human cardiac cells. Furthermore, nifedipine, ranolazine, and E4031 had similar effects on cardiomyocyte electrophysiology in both cell types. However, ranolazine and E4031 induced early after depolarization-like events and high intrinsic firing rates at lower concentrations in iCell CMC. These data show that VSDs provide a minimally invasive, quantitative, and accurate method to assess hiPSC-CM electrophysiology and detect subtle drug-induced effects for drug safety screening while highlighting a need to standardize experimental protocols across preparations.
No takes yet. Share an insight, caveat, or question.
Hortigón-Vinagre et al. (2016) studied Cardiac drug safety screening. Voltage-sensitive fluorescent dye di-4-ANEPPS was evaluated on Action potential duration (APD90) (p=< 0.01). Voltage-sensitive fluorescent dyes provided an accurate method to assess hiPSC-CM electrophysiology, detecting significant differences in APD90 between Cor.4U (229 ms) and iCell (427 ms) cells.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: