Key result
A semiautomatic line tracking algorithm using active contour models successfully reconstructed two- and three-dimensional heart wall motion from tagged MR images.
Design
Other
Authors
Loading...
May streamline tagged MR analysis of wall motion; leaves open clinical validation before adoption.
The study presents a novel semiautomatic algorithm using active contour models to track MR tissue tagging stripes for reconstructing 2D and 3D heart wall motion.
Young et al. (2002) studied Heart wall motion. Semiautomatic line tracking algorithm (active contour models) was evaluated on Reconstruction of two- and three-dimensional heart wall motion. A semiautomatic line tracking algorithm using active contour models successfully reconstructed two- and three-dimensional heart wall motion from tagged MR images.