Key result
EWI-based dispersion metric distinguishes His-bundle pacing from BiV, RVP, and LBBB via lowest activation spread.
Why the study?
Novel CRT delivery strategies such as His-Bundle pacing have emerged alongside conventional BiV pacing, motivating the introduction of a new EWI-based dispersion metric to further characterize ventricular activation.
Does an EWI-based dispersion metric accurately characterize ventricular activation across different cardiac resynchronization therapy pacing schemes?
Observational (n=43)
Does an EWI-based dispersion metric accurately characterize ventricular activation across different cardiac resynchronization therapy pacing schemes?
A novel EWI-based dispersion metric can effectively characterize ventricular activation and distinguish physiological His-bundle pacing from other pacing modalities and LBBB.
Answers are grounded in this paper and cite their sources.
May aid CRT pacing assessment via EWI; leaves open prospective validation before clinical use.
Conventional biventricular (BiV) pacing cardiac resynchronization therapy (CRT) is an established treatment for heart failure patients. Recently, multiple novel CRT delivering technologies such as His-Bundle pacing have been investigated as alternative pacing strategies for optimal treatment benefit. Electromechanical Wave Imaging (EWI), a high frame-rate echocardiography-based modality, is capable of visualizing the change from dyssynchronous activation to resynchronized BiV-paced ventricles in 3D. This proof-of-concept study introduces a new EWI-based dispersion metric to further characterize ventricular activation. Patients with His-Bundle device implantation (n = 4), left-bundle branch block (n = 10), right-ventricular (RV) pacing (n = 10), or BiV pacing (n = 15) were imaged, as well as four volunteers in normal sinus rhythm (NSR). EWI successfully mapped the ventricular activation resulting from His-Bundle pacing. Additionally, very similar activation patterns were obtained in the NSR subjects, confirming recovery of physiological activation with His pacing. The dispersion metric was the most sensitive EWI-based metric that identified His pacing as the most efficient treatment (lowest activation time spread), followed by BiV and RV pacing. More specifically, the dispersion metric significantly (p < 0.005) distinguished His pacing from the other two pacing schemes as well as LBBB. The initial findings presented herein indicate that EWI and its new dispersion metric may provide a useful resynchronization evaluation clinical tool in CRT patients under both novel His-Bundle pacing and more conventional BiV pacing strategies.
No takes yet. Share an insight, caveat, or question.
Melki et al. (2022) conducted an observational in Heart failure and pacing indications (n=43). Electromechanical Wave Imaging (EWI) dispersion metric vs. Conventional pacing schemes (BiV, RV) and LBBB was evaluated on Ventricular activation time spread (dispersion metric) (p=<0.005). An EWI-based dispersion metric distinguished His-Bundle pacing from biventricular pacing, right-ventricular pacing, and LBBB by identifying the lowest activation time spread.