Key result
CPM-enhanced virtual replicas accurately predict wavefront trajectories in fibrotic cardiac tissue with ~0.83 spatial correlation.
Why the study?
Virtual replicas aim to replicate biopotential conduction directly, but clinical use relies on non-invasive methods, challenging the understanding of virtual replica applicability limits.
A Cellular Potts model-enhanced virtual replica accurately predicts wavefront trajectories in fibrotic cardiac tissue, demonstrating that approximating fibrosis distribution is crucial for improving prediction accuracy.
May improve in silico arrhythmia prediction in fibrotic tissue; leaves open human validation.
In precision cardiology, virtual replicas (VRs) hold promise for predicting arrhythmias by leveraging patient-specific data and biophysics knowledge. A crucial first step is creating VRs of cardiac tissue based on retrospective patient data. However, VRs aim to replicate biopotential conduction directly, whereas only non-invasive methods are feasible for clinical use on real organs and tissues. This discrepancy challenges our understanding of VR applicability limits. This study aims to enhance the mathematical template of VR by developing an in vitro validation complement. We performed a frame-by-frame comparison of in vitro optical mapping of biopotential conduction with VR predictions. Patient-specific self-organized tissue samples from human induced pluripotent stem cell-derived cardiomyocytes (CMs) with diffuse fibrosis were utilized as VR prototypes. High-resolution optical mapping recordings (Δx = 117 ± 4 μm, Δt = 7.69 ms) and immunostaining were used to reproduce fibrotic samples of linear size 7.5 mm. We applied data-driven Bayesian optimization of the Cellular Potts model (CPM) to study wave propagation at the subcellular level. The modified CPM accurately reflected the "perinatal window" until the 20th day of differentiation, affecting CMs' self-organization. The percolation threshold of virtual conductive pathways reached 0.26 (0.27 ± 0.03 of CMs in vitro), yielding a spatial correlation of amplitude maps with Pearson's coefficients of 0.83 ± 0.02. As a proof-of-concept, we demonstrated that CPM-enhanced VR could predict wavefront trajectories in optical mapping recordings, showing that approximating fibrosis distribution is crucial for improving VR prediction accuracy.
No takes yet. Share an insight, caveat, or question.
Naumov et al. (2025) studied Fibrotic cardiac tissue. Cellular Potts model (CPM)-enhanced virtual replica vs. In vitro optical mapping was evaluated on Spatial correlation of amplitude maps (Pearson's coefficient 0.83 ± 0.02). CPM-enhanced virtual replicas accurately predicted wavefront trajectories in fibrotic cardiac tissue, yielding a spatial correlation of amplitude maps with Pearson's coefficients of 0.83 ± 0.02.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: