Answers are grounded in this paper and cite their sources.
• Split louvers improve daylighting performance and reduce lighting energy use. • Optimal positioning ensures well-distributed daylight with parametric control. • Parametric split louvers outperform conventional ones in daylight distribution. • Significant energy savings: 69.9% (March), 43.6% (June), 63.5% (December). The incorporation of split louvers into building systems provides substantial potential for enhancing daylighting performance and, consequently, reducing lighting energy consumption. This study focuses on the critical aspect of determining the optimal positioning of split louver sections to ensure well-distributed daylight in indoor spaces and adding parametric control as a daylight redirection system. This research aims to investigate indoor daylight environments by modifying the relationships and configurations of split louver sections and enhancing the efficiency of daylighting performance through the parametric control of the split louver. In addition, it investigates the energy-saving potentials of using the parametric split louver through the reduction of electric lighting consumption. The study demonstrates that the daylighting performance of the split louver depends upon the status of each section. Specifically, the effects of the upper section of the split louver are predominantly apparent in the rear area of the room, whereas the lower section markedly enhances illumination in the frontal area near windows, particularly during winter months when the lower solar angles. Secondly, the daylighting efficiency of the parametric split louver outperforms that of the conventional single louver in terms of daylight distribution and availability. The efficient daylight performance is evident in the uniform distribution of illuminance within the useful daylight illuminance (UDI) range of 300-500 lux on all typical dates, reaching 44% and 55% during the morning and noon, respectively, on March 21 st . Additionally, the electric lighting efficiency of the parametric split louver surpasses conventional louver throughout the day for all typical dates, resulting in notable lighting energy savings, with average percentages 69.9% and 63.5% on March 21 st and December 21 st , respectively, while June 21 st shows lower efficiency with 43.63% savings. This study contributes valuable insights for architects and designers seeking to create energy-efficient and well-illuminated indoor environments through the integration of parametric split louver.
No takes yet. Share an insight, caveat, or question.
Alsukkar et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: