Answers are grounded in this paper and cite their sources.
PURPOSE: The impact of a gravimetric-based technology-assisted workflow (TAWF) system on hazardous compounded sterile product (CSP) production time, staff perception of safety, and job satisfaction was evaluated. METHODS: For 2 weeks before implementation of a gravimetric-based TAWF, staff utilized an automated punch clock to document the time to prepare and check CSPs compounded volumetrically. Simultaneously, an anonymous, online survey was e-mailed to staff to evaluate their perceptions regarding the safety of volumetric preparation and satisfaction with their role preparing CSPs. At 30 and 90 days postimplementation of the TAWF, staff completed identical follow-up surveys to evaluate safety and satisfaction using the gravimetric-based TAWF. The TAWF software captured product preparation and check times postimplementation. Data regarding the accuracy of compounding were collected postimplementation and compared to accuracy data available in the published literature. Survey respondents preferred to use the TAWF to compound CSPs over volumetric preparation. There was no difference in respondents' perception of safety and accuracy of the TAWF preimplementation versus postimplementation. CONCLUSION: The gravimetric-based TAWF preparation of hazardous CSPs was faster and more accurate than manual volumetric preparation and improved staff perception regarding the accuracy of the CSP preparation process.
No takes yet. Share an insight, caveat, or question.
Roberts et al. (2018) studied this question.