Why the study?
Heterogeneity and homogeneity in flow-mediated dilation of individual human extremities are not fully understood, and the relationship between flow-mediated dilation and local muscle activity is unclear.
Does local muscle activity correlate with flow-mediated dilation in individual extremities in healthy young males?
Cross-Sectional (n=13)
Does local muscle activity correlate with flow-mediated dilation in individual extremities in healthy young males?
Absolute Event Rate: 8% vs 5.5%
p-value: p=<0.05
Flow-mediated dilation exhibits heterogeneity across individual extremities and correlates with local muscle activity, suggesting that local vascular function assessments should account for extremity dominance and muscle activity.
Objectives Heterogeneity and homogeneity in the flow-mediated dilation of the human body's individual extremities are not fully understood, and the relationship between flow-mediated dilation and local muscle activity is unclear. We assessed the flow-mediated dilation of four individual extremities and sought to determine the contribution of local muscle activity (evaluated as muscle strength) to the flow-mediated dilation in each extremity. Methods Thirteen healthy young right-handed nonactive males participated. The flow-mediated dilation in the brachial and popliteal arteries at both arms and legs was assessed by ultrasound Doppler. Muscle strength was evaluated as the grip strength and knee extension. Results There was a significant difference in the brachial artery (BA)-FMD values between the subjects' dominant and non-dominant sides (8.0 ± 2.8 vs. 5.5 ± 2.2%, p < 0.05), whereas the two sides showed similar popliteal artery (PA)-FMD values. There was no significant correlation in flow-mediated dilation between the dominant brachial artery and popliteal artery. The BA-FMD was significantly correlated with the grip strength in both upper extremities (dominant: r = 0.562, non-dominant: r = 0.548; p < 0.05, respectively). Conclusion These results demonstrated heterogeneity in the flow-mediated dilation of individual extremities. We observed that local muscle activity can affect the local vascular function. Measurements of vasodilatory function in individual extremities should thus be carefully considered.
No takes yet. Share an insight, caveat, or question.
Kadoguchi et al. (2019) conducted a cross-sectional in Healthy (n=13). Dominant side vs. Non-dominant side was evaluated on Brachial artery flow-mediated dilation (BA-FMD) (p=<0.05).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: