Key result
Internal fixation using a sliding screw-plate device for low-energy subtrochanteric fractures in elderly patients achieved a 91% satisfactory union rate among survivors.
Why the study?
Does internal fixation with a sliding screw-plate device result in satisfactory union in elderly patients with low-energy subtrochanteric fractures?
Observational (n=31)
Does internal fixation with a sliding screw-plate device result in satisfactory union in elderly patients with low-energy subtrochanteric fractures?
A sliding screw-plate device is a reliable implant for low-energy subtrochanteric fractures in elderly patients, achieving a 91% union rate among survivors despite high early mortality.
Answers are grounded in this paper and cite their sources.
Case reports leave sliding screw-plate efficacy open in elderly subtrochanteric fractures; randomized trials needed before practice change.
Forty-two patients with subtrochanteric fractures were treated from 1987 through 1990. Of these, 31 patients above 70 years of age (average, 81.9) had nonpathologic low-energy fractures that were internally fixed with a sliding screw-plate device. Subtrochanteric fractures with an associated intertrochanteric component were the most common type. Interfragmentary compression was used in long oblique and spiral fractures and those with large butterfly fragments. Patients were mobilized early and allowed partial weightbearing for 6-8 weeks. There was a 29% mortality rate within 3 months of injury. Of the remaining cases, followed for a minimum of 6 months (average, 11.8 months), 20 (91%) united satisfactorily. There was loss of fixation in one case and one instance of plate fracture. We found, given the special circumstances in elderly patients, that the device was suitable not only for subtrochanteric fractures with an intertrochanteric element but also for four-part fractures and two-part spiral fractures. The sliding screw-plate permitted passage of interfragmentary screws and facilitated medial displacement and collapse, which are valuable in cases with medial comminution in reducing the bending moment on the plate. These factors may help reduce the incidence of plate failure and, coupled with familiarity with its use, make it a reliable implant for such difficult fractures in elderly patients.
No takes yet. Share an insight, caveat, or question.
Mullaji et al. (1993) conducted an observational in Low-energy subtrochanteric fractures (n=31). Internal fixation with a sliding screw-plate device was evaluated on Satisfactory union. Internal fixation using a sliding screw-plate device for low-energy subtrochanteric fractures in elderly patients achieved a 91% satisfactory union rate among survivors.
Synapse has enriched 10 related papers. Consider them for comparative context: