Key result
Transvenous catheter cryoablation successfully achieved transient high degree and complete AV block in 100% (5/5) of dogs without any adverse effects.
Transvenous catheter cryoablation effectively creates complete AV block in a canine model, with intracardiac echocardiography allowing visualization of iceball formation without microcavitation.
We investigated the use of a catheter-based cryoablation system on atrioventricular (AV) junction ablation in dogs. In five dogs, the cryoablation catheter was introduced to the AV junction area in order to create transient high degree or complete AV block. Cryo-freezing energy was applied by lowering the temperature to -75 degrees C for five minutes as a single cycle. This cycle was repeated until significant impairment of the AV conduction appeared. Transient high degree and complete AV block was obtained in all five dogs without any adverse effects. The iceball formation was identified by intracardiac echocardiography. Ablation of the AV junction is effective with several freeze-thaw cycles using a transvenous catheter cryoablation system.
No takes yet. Share an insight, caveat, or question.
Okishige et al. (2004) studied Atrioventricular junction ablation (n=5). Transvenous catheter cryoablation was evaluated on Transient high degree or complete AV block. Transvenous catheter cryoablation successfully achieved transient high degree and complete AV block in 100% (5/5) of dogs without any adverse effects.