Key result
Cryoballoon ablation for paroxysmal atrial fibrillation yielded an incremental cost-utility ratio of £152,836 per QALY gained compared to radiofrequency ablation, exceeding standard cost-effectiveness thresholds.
Why the study?
The study evaluated the cost-effectiveness of cryoballoon ablation compared to traditional irrigated radiofrequency ablation for pulmonary vein isolation in patients with drug-refractory paroxysmal AF.
Is cryoballoon ablation cost-effective compared to radiofrequency ablation in patients with paroxysmal atrial fibrillation refractory to antiarrhythmic drug therapy?
Is cryoballoon ablation cost-effective compared to radiofrequency ablation in patients with paroxysmal atrial fibrillation refractory to antiarrhythmic drug therapy?
Cryoballoon ablation for paroxysmal atrial fibrillation provides a marginal QALY benefit at a higher cost compared to radiofrequency ablation, resulting in a high incremental cost-effectiveness ratio.
Answers are grounded in this paper and cite their sources.
Cryoballoon ablation exceeds cost-effectiveness thresholds versus radiofrequency ablation; reinforces preference for the latter and supports targeted economic evaluations in paroxysmal atrial fibrillation.
INTRODUCTION: The objective of this study was to evaluate the cost-effectiveness of the treatment with cryoballoon (CB) compared to the standard treatment with traditional irrigated radiofrequency (RF) ablation for pulmonary vein isolation in patients with paroxysmal atrial fibrillation (pAF) refractory to antiarrhythmic drug therapy. METHODS: A decision tree model was developed to graphically depict the probabilities, utilities and costs of CB compared to RF therapy. Data from a conducted systematic literature review and meta-analysis of only RCTs were used to evaluate clinical outcomes of CB and RF treatments, including success rates after one year, complications and recurrence of atrial fibrillation. RESULTS: The cost-utility analysis estimated that, CB therapy had £1,747 higher cost, and 0.0114 more quality-adjusted life years (QALYs) compared to standard RF treatment over a one-year time horizon. The incremental cost per QALY of CB ablation compared to RF ablation was estimated to be £152,836/QALY. CONCLUSIONS: Based on current evidence, CB ablation for pulmonary vein isolation in patients with pAF is costeffective compared to RF if decision makers are willing to pay £152,836 or higher for a QALY.
No takes yet. Share an insight, caveat, or question.
Marie‐Isabel Murray (2018) studied Paroxysmal Atrial Fibrillation (pAF). Cryoballoon (CB) ablation vs. Radiofrequency (RF) ablation was evaluated on Incremental cost-utility ratio (ICUR) (ICUR £152,836/QALY). Cryoballoon ablation for paroxysmal atrial fibrillation yielded an incremental cost-utility ratio of £152,836 per QALY gained compared to radiofrequency ablation, exceeding standard cost-effectiveness thresholds.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: