Key result
Non-contact mapping accurately identified the location of right-sided accessory pathways, enabling successful radiofrequency ablation of 9 out of 9 pathways in 6 patients.
Why the study?
Does a non-contact mapping system accurately localize right-sided accessory pathways for catheter ablation in patients with type B Wolff-Parkinson-White syndrome?
Observational (n=6)
Does a non-contact mapping system accurately localize right-sided accessory pathways for catheter ablation in patients with type B Wolff-Parkinson-White syndrome?
Non-contact mapping accurately and quickly localizes right-sided accessory pathways for catheter ablation in type B Wolff-Parkinson-White syndrome.
May facilitate right-sided pathway ablation in WPW; hypothesis-generating from small case series and requires prospective validation.
AIMS: Ablation of right-sided accessory pathways (APs) is sometimes challenging because several anatomical features of the tricuspid annulus (TA) and surrounding structures differ from those of the mitral annulus. This study investigated the electrophysiological characteristics and efficacy of a non-contact mapping (NCM) system for catheter ablation of right-sided APs. METHODS AND RESULTS: We examined nine APs in six consecutive patients who underwent catheter ablation of right-sided APs with NCM. In Case 6, we compared NCM with contact activation mapping. Three of six patients had two APs, and one of these had previously failed ablation. We observed atrial activation during sinus rhythm or atrial pacing using a multiple-electrode array (MEA) deployed in the right atrium near the TA. Non-contact mapping identified the AP location as a peri-TA breakout point that appeared prior to or simultaneously with the delta wave onset in all APs. In Case 6 we confirmed that the peri-TA breakout identified by NCM corresponded to the earliest ventricular activation identified by contact mapping. We successfully ablated nine APs by radiofrequency (RF) energy application to the breakout sites, while one AP located just above the pole of the MEA required additional conventionally guided mapping and ablation. The mean RF duration was 189.8 ± 119.0 s. After 33.2 ± 9.4 months of follow-up, one para-hisian AP and one right lateral AP recurred, but these were successfully ablated in a second procedure using NCM. CONCLUSION: Non-contact mapping was able to identify the location of right-sided APs accurately and quickly.
No takes yet. Share an insight, caveat, or question.
Nishida et al. (2011) conducted an observational in Type B Wolff-Parkinson-White syndrome with right-sided accessory pathways (n=6). Non-contact mapping (NCM) system was evaluated on Successful ablation of accessory pathways. Non-contact mapping accurately identified the location of right-sided accessory pathways, enabling successful radiofrequency ablation of 9 out of 9 pathways in 6 patients.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: