Key result
1D Squeeze U-net model accurately estimates BP from raw PPG signals with ~4 mmHg systolic error.
Why the study?
Measuring continuous BP in real time via an mHealth application could advance healthcare, prompting development of a cuffless measurement method from a digital artery.
Does a 1D Squeeze U-net model using raw PPG signals accurately estimate continuous blood pressure in real time?
Does a 1D Squeeze U-net model using raw PPG signals accurately estimate continuous blood pressure in real time?
A novel 1D Squeeze U-net deep learning model using raw PPG signals accurately estimates continuous blood pressure, meeting British Hypertension Society and AAMI standards.
May support real-time cuffless BP monitoring; leaves open prospective validation before clinical use.
Measuring continuous blood pressure (BP) in real time by using a mobile health (mHealth) application would open a new door in the advancement of the healthcare system. This study aimed to propose a real-time method and system for measuring BP without using a cuff from a digital artery. An energy-efficient real-time smartphone-application-friendly one-dimensional (1D) Squeeze U-net model is proposed to estimate systolic and diastolic BP values, using only raw photoplethysmogram (PPG) signal. The proposed real-time cuffless BP prediction method was assessed for accuracy, reliability, and potential usefulness in the hypertensive assessment of 100 individuals in two publicly available datasets: Multiparameter Intelligent Monitoring in Intensive Care (MIMIC-I) and Medical Information Mart for Intensive Care (MIMIC-III) waveform database. The proposed model was used to build an android application to measure BP at home. This proposed deep-learning model performs best in terms of systolic BP, diastolic BP, and mean arterial pressure, with a mean absolute error of 4.42, 2.25, and 2.56 mmHg and standard deviation of 4.78, 2.98, and 3.21 mmHg, respectively. The results meet the grade A performance requirements of the British Hypertension Society and satisfy the AAMI error range. The result suggests that only using a short-time PPG signal is sufficient to obtain accurate BP measurements in real time. It is a novel approach for real-time cuffless BP estimation by implementing an mHealth application and can measure BP at home and assess hypertension.
No takes yet. Share an insight, caveat, or question.
Athaya et al. (2022) studied Blood pressure estimation (n=100). 1D Squeeze U-net model using raw PPG signal was evaluated on Mean absolute error for systolic BP, diastolic BP, and mean arterial pressure. A 1D Squeeze U-net model using raw PPG signals accurately estimated systolic BP, diastolic BP, and MAP with mean absolute errors of 4.42, 2.25, and 2.56 mmHg, respectively.