Fingertip magnetic sensors accurately detect pulse signals with ~0.95 correlation to vibrational signals.
Why the study?
Existing wearable pulse-detection devices are sensitive to skin conditions or require external stimuli to penetrate skin, leading to motion artifacts and unsuitability for challenging skin conditions.
Does a fingertip-type magnetically detected vibration sensor accurately detect pulse signals under unusual monitoring conditions compared to standard vibrometers in healthy subjects?
Does a fingertip-type magnetically detected vibration sensor accurately detect pulse signals under unusual monitoring conditions compared to standard vibrometers in healthy subjects?
Effect estimate: Correlation coefficient 0.9527-0.9924
A novel fingertip-type magnetic pulse detection device can accurately measure pulse signals even under challenging conditions like opaque coverings or water immersion, offering a robust alternative to optical sensors.
Offers potential for reliable pulse detection in non-ideal settings; leaves open clinical utility pending prospective validation.
Wearable devices for continuous non-invasive monitoring of physiological signals are crucial for preventive care and management of chronic conditions. However, these devices are either sensitive to skin conditions or require external stimuli, such as light or electrical excitation, to penetrate the skin for pulse detection. This often results in large motion artifacts and unsuitability for certain skin conditions. Here we demonstrate a simple fingertip-type device which can detect clear pulse signals under a range of conditions, including fingers covered by opaque substances such as a plaster or nail polish, or fingers immersed in water. The structure of the device consists of a pair of magnets and a magnetic sensor. Both experimental and numerical results show that the detected pulsation signals correspond directly to the vibrations induced by blood circulation with negligible influence from modulated magnetic signature of blood. Therefore, this device could be used in conditions which are challenging for existing pulse detectors and might also have its application extended to blood pressure measurement.
No takes yet. Share an insight, caveat, or question.
Shen et al. (2023) studied Healthy subjects. Fingertip-type magnetically detected vibration sensor (MDVS) vs. Vibrometer and commercial PPG was evaluated on Correlation between magnetic and vibrational signals (Correlation coefficient 0.9527-0.9924). The fingertip-type magnetically detected vibration sensor accurately detected pulse signals under challenging conditions, demonstrating a high correlation (0.9527-0.9924) with vibrational signals.