Answers are grounded in this paper and cite their sources.
This paper presents a method for improving the efficiency and reducing the noise of LLC converters as a feature of LLC converters. And in DCM mode, the rectifier circuit can operate in ZCS mode, so no recovery current flows. However, when applied to a wide range of voltages, such as in an automotive charger, the reactive current may increase. In addition, when the output voltage is low, DCM operation is not possible and recovery current flows, causing a decrease in efficiency. To solve these problems, we present a method that uses multi-level conversion technology to solve these problems. Since this is an in-vehicle charger application, it is configured as an AC-DC converter. We show a control method to balance the load with a PFC converter based on the variation of resonant circuit parameters.
No takes yet. Share an insight, caveat, or question.
Susumu Ohba (2024) studied this question.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: