Critical temperature, critical pressure, and vapor pressure measurements have been performed on 15 compounds by a flow method with ultralow residence times. These compounds are γ-butyrolactone, di(propylene glycol), 1,3-butanediol, N-methyldiethanolamine, 4-formylmorpholine, 1,2-epoxy-2-methylpropane, diethyl oxalate, n-butyl acrylate, 2-(2-aminoethoxy)ethanol, tert-butyl acetate, 1,1-ethanediol diacetate, p-diisopropylbenzene, dimethyl disulfide, oxazole, and phenyl isocyanate. Accurate vapor pressure data are also included for di-n-butyl disulfide and sulfolane, but these compounds proved too unstable to directly determine the critical constants using this apparatus.
No takes yet. Share an insight, caveat, or question.
VonNiederhausern et al. (2006) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: