Key result
Commercial wearables track HR with ~5% error during golf but poorly estimate energy expenditure.
Why the study?
The study evaluated the accuracy of commercially available wearable devices for measuring heart rate and energy expenditure during golf.
Do commercially available wearable devices accurately estimate heart rate and energy expenditure during golf compared to criterion measures in healthy male golfers?
Observational (n=14)
No
Do commercially available wearable devices accurately estimate heart rate and energy expenditure during golf compared to criterion measures in healthy male golfers?
Wearable devices provide highly accurate heart rate measurements during golf, but energy expenditure accuracy varies by device and activity type.
Wearables may support HR monitoring during golf but not EE estimates; leaves open device-specific validation needs.
PURPOSE: This study examined the accuracy of the heart rate (HR) and energy expenditure (EE) measured by commercially available wearable devices during golf.METHODS: A total of 14 male golfers (24.0±4.06 years) participated in this study. Each participant wore five wearable devices (Apple Watch Series 2, AS; Fitbit Versa, FV; Polar V800, PV; Samsung Galaxy Watch Active, SA; and Suunto Spartan Sport Wrist HR, SWH) on the wrist in the laboratory and/or on a golf course. The criterion measures used to evaluate the accuracy of the HR and EE entailed a wireless heart rate monitor (Polar V800, Polar, Finland) and portable indirect gas analyzer (K4b2, COSMED, Italy). In the laboratory, the participants walked on a treadmill and swung golf clubs using seven iron. On the golf course, the participants played golf in nine holes.RESULTS: In the laboratory, the mean absolute percentage error (MAPE) of the HR in the five wearable devices was within 8% for walking and golf club swinging, excluding FV (12%). The MAPE in EE was within 15% for SA, AS, and PV when walking at a speed of 5.6 km/h on the treadmill, but the MAPE in golf club swinging were within 25%. On the golf courses, the HR in all wearable devices showed the MAPE of <5% but EE showed an error rate of <20%, excluding SWH (73%).CONCLUSIONS: The findings of this study suggest that wearable devices might be used to monitor intensity and amount of exercise during golf.
No takes yet. Share an insight, caveat, or question.
Lee et al. (2022) conducted an observational in Healthy male golfers (n=14). Wearable devices (Apple Watch, Fitbit, Polar, Samsung, Suunto) vs. Criterion measures (Polar V800, COSMED K4b2) was evaluated on Mean absolute percentage error (MAPE) of heart rate and energy expenditure. Commercially available wearable devices measured heart rate with high accuracy (MAPE <5%) during golf, but energy expenditure estimation showed variable error rates (<20% for most devices, 73% for Suunto).